Manufacturer's recommendations :
• Read attentively the manufacturer's instructions.
• Positioning of the lamp and connecting the power supply require great care. To make sure there is a good
conduction of current, the mechanical support and the electrical connections must be free from dirt and corrosion.
The clamps and brackets must be checked whenever the lighting unit has been transported.
• The lamp emits ultraviolet radiation. Direct exposure can be harmful to your health.
• It is recommended to avoid air draughts, also avoid exposing the lighting unit to bad weather.
• Use only when bulb in place
Technical characteristics :
Voltage at the terminals of the lamp : ....................................................100 V
Amperage at the terminals of the lamp : ..............................................13,8 A
Luminosity of the lamp : ..................................................................110 000 lm
Luminous efficacy : ................................................................................ 92 lm/W
Colour temperature : .................................................................................5600 K
Base : ......................................................................................................SFa 15,5-6
Manufacturer's rated life : ......................................................750/1000 hours
User's precautions :
• The lamplife, as given by the manufacturer, is a theoretic lamplife duration as "in laboratory conditions",
a cycle based on 3 hours on / 1 hour off. Briefer cycles reduce the duration of the lamplife.
• In operating conditions, it is uncommon, for the lamp to still be fully efficient after 200 to 300 hours.
Its efficiency can decrease by 30%.
• Premature wearing of lamp under performing conditions is mainly due to frequent switching on. Better leave
the lamp on, through the performance, rather than switching it on repeatedly. ( The lamplife is reduced about
1 hour, each time the lamp is switched on ). It is advised to wait for 10 minutes before switching on again.
(This extends the duration of the lamp.)
New lamp :
• To achieve a good ionization of a new lamp, when using it for the first time, it is recommended to leave it on
for a few hours.
• Preserve carefully the guarantee slip of the lamp, as it may be asked for in the event to resolve a dispute.
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr
TECHNICAL FILE
FOLLOWSPOTS
ADMISSIBLE LAMPS
HMI 1200W
LUCY / SK /
FLO / VICTOR
Section A - 9
MSR 1800W
100 V
20 A
145 000 lm
80 lm/W
6000 K
SFa 15,5-6
750 hour