Herunterladen Diese Seite drucken

Werbung

PMLCD - PMLCD/L - PMLED - PMLED/5 – 3-1/2D DIGITAL PANEL METER
1. Introduction
To all residents of the European Union
Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm
the environment.
Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialised
company for recycling.
This device should be returned to your distributor or to a local recycling service.
Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for buying our product! Please read the manual thoroughly before bringing this device into service.
If the device was damaged in transit, don't install or use it and contact your dealer.
2. Features
• 200mV full scale input sensitivity
• Decimal point selectable
• 14mm (0.56") figure height
• Automatic polarity indication
• Guaranteed zero reading for 0V input
• High input impedance (> 100Mohm)
3. Applications
Voltmeter, thermometer, PH meter, dB meter, Watt meter, current meter, capacitance meter, Lux meter, LCR meter,
other industrial & domestic uses
4. Specifications
Maximum input
Maximum display
Indication method
Measurement method
Over range indication
Reading rate time
Input impedance
Accuracy
Power dissipation
Decimal point
Supply voltage
Size
5. Operation
- If needed, add proper voltage dividers (not included) and decimal point wire jumper:
(RA and RB are 1/2 W 0.5% metal film resistors)
PMLCD - PMLCD/L - PMLED - PMLED/5
199.9mVDC
1999 counts (3-1/2 digits) with automatic polarity indication
PMLED(/5): LED display; PMLCD(/L): LCD display
Dual-Slope integration A/D converter system
"1" shown in the display
2 - 3 readings per sec
>10M
+/- 0.5% (23° +/- 5°C, <80% RH)
50 - 60mA DC
Selectable with wire jumper
PMLED/5: +5VDC; others: +9VDC
68 x 44mm
- 1 -
VELLEMAN

Werbung

loading

Inhaltszusammenfassung für Velleman PMLCD

  • Seite 1 PMLCD - PMLCD/L - PMLED - PMLED/5 – 3-1/2D DIGITAL PANEL METER 1. Introduction To all residents of the European Union Important environmental information about this product This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment.
  • Seite 2 - Connect the input voltage to be measured to +Vin and -Vin. The input voltage should be DC only. The information in this manual is subject to change without prior notice. PMLCD - PMLCD/L - PMLED - PMLED/5 – 3-1/2D DIGITALE PANEELMETER 1. Inleiding...
  • Seite 3 - Sluit de te meten ingangsspanning aan op Vin en op GND. De ingangsspanning mag enkel gelijkspanning (DC) zijn. De informatie in deze handleiding kan te allen tijde worden gewijzigd zonder voorafgaande kennisgeving. PMLCD - PMLCD/L - PMLED - PMLED/5 – AFFICHEUR NUMÉRIQUE 3-1/2D 1. Introduction Aux résidents de l'Union européenne...
  • Seite 4: Caractéristiques

    4. Spécifications Entrée maximale 199.9mVCC Affichage maximal 1999 points (3-1/2 digit) avec indication automatique de la polarité PMLED(/5) : afficheur LED ; PMLCD(/L) : afficheur LCD Méthode d'affichage Méthode de mesure Système de conversion d'intégration A/D Dual-Slope Indication de surcharge "1"...
  • Seite 5: Especificaciones

    PMLCD - PMLCD/L - PMLED - PMLED/5 – INSTRUMENTO DE PANEL DIGITAL 3-1/2D 1. Introducción A los ciudadanos de la Unión Europea Importantes informaciones sobre el medio ambiente concerniente este producto Este símbolo en este aparato o el embalaje indica que, si tira las muestras inservibles, podrían dañar el medio ambiente.
  • Seite 6 - Conecte la tensión de entrada que quiere medir a los puntos +Vin y -Vin. La tensión siempre debe ser una tensión continua (CC). Se pueden modificar las especificaciones y el contenido de este manual sin previo aviso. PMLCD - PMLCD/L - PMLED - PMLED/5 – 3-1/2-STELLIGES DIGITALES PANELMETER 1. Einführung An alle Einwohner der Europäischen Union Wichtige Umweltinformationen über dieses Produkt...
  • Seite 7: Technische Daten

    (z.B. 100V für 200V-Bereich) und regeln Sie vorsichtig den Widerstand R2 bis Sie dieselbe Anzeige wie auf dem Display erreichen. - Schließen Sie die zu messende Eingangsspannung an +Vin und –Vin an. Die Eingangsspannung darf nur Gleichstrom sein. Alle Änderungen vorbehalten. PMLCD - PMLCD/L - PMLED - PMLED/5 - 7 - VELLEMAN...

Diese Anleitung auch für: