7.
Functional description of the transmitters
Opus
-Funk Plus wall transmitter
®
Button O
Button I
7.1 Two-button function (Function 1)
Button I switches consumers on and button O switches
them off. Standard function and motion sensor function!
Button
Function
Press button O
Switch off
Press button I
Switch on
Parameter
No adjustable parameters!
7.2 One-button function (Function 2)
Activating either button I or button O will cause the consumer's
state to toggle.
Button
Function
Press button I or button O
Switch on/off
Parameter
1
Button O is activated
2
Button I is activated
3
Button I and button O are activated
7.3 Momentary contact (Function 3)
The consumer will switch on when either button I or button O
is pressed and switch off again when the button is released.
Button
Press button I or button O
Release button I or button O
Parameter
1
Button O is activated
2
Button I is activated
3
Button I and button O are activated
7.4 Stairwell light with switch-off alarm (Function 4)
The consumer will switch on for a preset period of time
(parameter) when either button I or button O is pressed.
Once the time expires, the light will be switched off for 2 s
(switch-off alarm) then switch on again for another 30 s.
Button
Function
Press button I or button O
Switch on with running
time (parameter)
Parameter
1
Running time 2 min
2
Running time 1 min
3
Running time 5 min
4
Running time 10 min
5
Running time 20 min
6
Running time 30 min
7
Running time 60 min
8
Running time 120 min
7.5 Timer switching (Function 5)
Pressing button I will switch on the consumer for the preset
period of time (parameter).
Button O will switch off the consumer before timer timeout.
Button
Function
Press button I
Switch on with running time
(parameter)
Press button O
Switch off
Parameter
see Point 7.4
561312-Rev01_070122.pdf
7.6 Fan with start-up and stop delay (Function 6)
This function, in combination with Function 1, can be used to
implement a light with fan control by employing a 2-channel
Radio Plus actuator and one transmitter.
Button O
One actuator's channel is used for light control and the other is
used for fan control.
The transmitter must be assigned on the actuator and
Button I
appropriately programmed (e.g. to Function 1 for light control
over channel 1 and to Function 6 for fan control over channel 2).
Pressing button I will switch on the light; the fan will subse-
quently switch on after a 3 minute delay.
Pressing button O will switch off the light; the fan will remain on
for the preset (parameter) stop-time delay.
Button
Press button I
Press button O
Parameter
1
Running time 6 min
2
Running time 2 min
3
Running time 10 min
4
Running time 15 min
5
Running time 20 min
6
Running time 30 min
7.7 Light scenes (Function 7)
A light scene can be implemented with this function when
a light control with multiple Radio Plus actuators and their
assigned transmitters are available.
This is done by assigning all actuators involved in the light
scene to an additional transmitter, in which Function 7 has
been programmed for each of the actuators.
When respective actuators are to be switched on or off then
one of the buttons on the transmitter to be used must be
held depressed for more than 2s in order to store the light
Function
scene, which will be confirmed by a brief blinking of the
Switch on
output.
Switch off
By briefly pressing the transmitter's button I or button O,
one of the four stored light scenes (A-D) will be called up.
Button
Press button O briefly
Press button I briefly
Press button O for longer
Press button I for longer
Parameter
1
Light scene A (button O), light scene B (button I)
2
Light scene C (button O), light scene D (button I)
7.8 Window contact (Function 8)
Window contact
Magnet
When a assigned window contact is opened the consumer is
switched on. When all assigned window contacts are closed
the consumer is switched off.
Caution!! The magnetic contact must be assigned or deleted
with its programming button on a actuator.
Following activation of Function 8's programming, the
magnetic contact of the window contact must be activated one
time to permit its recognition! This can also be done before
the the window contact will be mounted.
Status of window contact
Window contact opened
All assigned window contacts
are closed
Parameter
No adjustable parameters!
Function
Switch on, time-delayed
(3 minutes)
Activates follow-up time
(parameter)
Function
Switch on light scene
A or C (parameter)
Switch on light scene
B or D (parameter)
Storage light scene
A or C (parameter)
Storage light scene
B or D (parameter)
max. 5mm
Function
Switch on
Switch off
8. Ranges between transmitters and actuators
The range of the Radio Plus radio signals decreases as the
distance between transmitter and actuator increases.
If the normal range between transmitter and actuator is
insufficient, an Radio Plus Repeater (561.400) can be
employed to increase range.
The range between the transmitter and actuator in a house
is approx. 30m (line-of-sight connection) and 100m in halls.
The transmission range depends on the materials used
in the building:
Material
Typical range
Masonry
20m (max. 3 walls)
Reinforced concrete
10m (max. 1 wall/ceiling)
Drywall/wood
30m (max. 5 walls)
Limiting the range of the radio signals due to:
• Installing the transmitter or actuator in the immediate vicinity
of materials with metal constituents, or metal objects.
A distance of at least 10 cm should be maintained.
• Installing the transmitter/actuator on the ground or at
ground level.
• Moisture in the materials
• Devices, which also emit high frequency signals, such as
e.g. computers, audio and video equipment, electronic
ballasts for illuminants.
A distance of at least 0.5m should be maintained.
9. Error analysis in the case of radio interference
For a new or pre-existing system:
• Check the system voltage of the actuator.
• Check if the actuator is receiving a radio command.
• Check if the actuator is connected as specified.
• Check the operation of the connected consumers.
• Delete all transmitters in the actuator, and reprogramme
the actuator.
• Check if any changes have been made around the system
that could generate problems (metal cabinets, walls or
furniture has been moved, etc.).
If possible, restore things to their original status.
• Mount the transmitter or actuator at a better location.
The actuator independently turns ON and OFF:
• This can occur when an outside transmitter is activated
within the actuator range that was previously programmed
in the actuator.
• Delete all transmitters in the actuator, and reprogramme
the actuator.
A transmitter does not work:
• Take the transmitter and move toward the actuator.
If the system still works at a closer distance, the transmitter
was installed outside of the transmission range, or there
was interference.
• Mount the transmitter or actuator at a better location.
10. Warranty
These operating instructions are an integral part of both the
appliance and the terms of warranty. They must be furnished
to the user. The technical design of the appliance is subject
to change without prior notification.
Jäger-Direkt products are manufactured using state of the
art technologies in compliance with prevailing national and
inter- national regulations, and are quality tested. The right
of compensation apllies according to payment terms and
delivery conditions of Jäger Direkt GmbH & Co. KG.
Further information to application and parameterisation for the
Opus radio plus product family under www.opus-schalter.de.
Jäger-Direkt Radio Plus products may be sold and used
in EU countries, Switzerland, Iceland and Norway.
The products conform to R&TTE Directive 1999/5/EC
and meet EU regulations.
GB - 2