10.0.3 PD Converter
●This function is used for only QC2.0 charger, But want to supply power to
PDappliances.
●Before use, Switch the PD communication switch to ON, Then enter the PDprotocol
conversion mode,after entering,Plug in PD appliances, You can performPD fast
charge.
●In this mode,C1ick the middle button and use the left and right buttons tochange the
maximum power of packets sent by the PD.When changing power,
exceed the charger power to avoid unnecessary
you must click the middle button to confirm.
●Set 5v when no device is connected,Avoid high-voltage damage to mobilephones
that do not support high-voltage when plugged in.
●QC2.0 only B type charger supports 20v trigger, So when the PD appliancerequests
20V voltage, The tester will detect whether the charger successfullytriggers
QC2.0-20V,If it does not reach 20V, The tester will cancel the 20V gear,And resend the
Caps broadcast.
10.0.4 USB-C-E-Marker
E-Marker cable refers to a cable with an E-Marker chip in the Type-C interface,If the
interface does not contain E-Marker chip, The packets from thePD charging head cannot
exceed 3A current, And only use the E-Marker cable to trigger the PD protocol, The
current can exceed 3A.
When using the USB-C electronic label,Except that the Type-C interface cannot be used
for power supply,PC port, USB-A, Micro-USB interface can all be usedforpowersup-
ply.The PD communication switch needs to be turned ON.
damage.Afterchanging the power,