Installation
1.
Flush the pipes, close shut-off valve afterwards.
2.
Connect adapter to magnetic valve.
3.
Remove blank plug.
4.
Insert magnetic valve, pull tight only by hand!
Switch off ower supply!
5.
Connect transformer to power supply and install it.
Connect electronic plate to transformer.
6.
Connect magnetic valve.
7.
Switch on power supply and open shut-off valve.
Hint:
Pay attention to correct polarity at plug connections!
Diagram – flushing quantities
Pressure
1 bar
2 bar
3 bar
4 bar
5 bar
OCEAN U8
2,0
5,5 s
4,5 s
3,0 s
2,5 s
2,5 s
Flush volume in liters
3,0
7,0 s
5,5 s
4,5 s
4,0 s
4,0 s
Urinal control
SanTec OCEAN U8
4,0
10,0 s
7,5 s
6,0 s
5,5 s
5,0 s
EN
13