Commissioning

6 Commissioning
6.1
WARNING
Electrical voltage! Danger to life!
¾ Only an authorised electrician may install and connect the device.
¾ Always disconnect from the mains network and secure against unin-
¾ The device must only be operated with an adapter and a correspond-
The wiring of a room-by-room temperature control system depends on
several factors and must be planned and carried through carefully by
the installer.
The following cross-sections are applicable for the plug-in/clamping
connections:
• rigid wire: 0.75 – 1.5 mm²
• flexible wire: 0.75 – 1.5 mm²
• 8 mm insulation stripped off the wire
When operating with electronic transformers, only use transformers
complying with the requirements according to DIN EN 61347-1 (VDE
0712-30, part 1) as well as DIN EN 61047 (VDE 0712-25, part 2).
Installation must only be performed in industrially available switchbox-
es (mounting boxes) according to DIN 49073-1.
The dimming actuator is exclusively used in a dimmer circuit:
1. Disconnect from the mains network and secure against unintended
2. If necessary pull off the rocker from the frame of the respective switch.
3. Pull off the frame and the clamping/support piece from the switch.
4. Loosen the cabling and remove the existing switch if necessary.
5. Connect the conductor to lamp/light to connection terminal
29
DEU

Installation

tended activation before mounting and installation.
ing and installed switch cover. Only remove the switch cover for con-
figuration purposes.
activation.
figure).
ENG
(see