RF Rx EN868-2W / RF Rx EN868-2W-RS232
//
Montage- und Anschlussanleitung / Funkempfänger
Mounting and wiring instructions / Radio receiver
Instructions de montage et de câblage / Récepteur radio
Istruzioni per il montaggio e per il collegamento / Ricevitore radio
Instruções de montagem e instalação / Receptor de rádio freqüência
Инструкции Монтаж и Коммутация / Приемник радиосигнала
English
pressing of the push-button S1 again, (approx. 1 s). If you do not press
the push-button S1 again the next operation mode is switched on after
5 s. The operation modes »Conjunction« and »Latching function« can
be selected in addition to the other operation modes.
Operation
LED 1
LED MD
mode
Standard
flashes
flashes
fast
fast
Standard
flashes
on
inverse output
fast
Relay ener-
on
flashes
gised
fast
Relay ener-
on
on
gised, inverse
output
Conjunction
flashes
on
slowly
Latching
on
flashes
function
slowly
Teaching in of switches
- press push-button S1 approx. 1 s
- LED MD flashes slowly (2 Hz)
- press push-button S2 for channel seletion
- actuate switch/command device to be taught in
- the LED of the corresponding channel flashes short
- to leave teach-in mode press push-button S1 for approx. 1 s
- LED MD is on
Deleting one switch
- press push-button S1 for 5 s until LED MD flashes fast
- press push-button S2 for channel seletion
- actuate switch/command device to be deleted
- the LED of the corresponding channel is off for short time
- press push-button S1 for approx. 1 s to leave delete mode
- LED MD lights green
Inverse teaching in of one switch
- procedure like teach-in but switch must be actuated before
procedure is started by pressing S1
Deleting all switches
- press push-button S1 for 5 s
- LED MD flashes fast (5 Hz)
- LED channel selection is on
- release push-button S1
Function
Relay energised by actuation
Relay de-energised by actua-
tion, inverse output signal
Relay energised by providing
operating voltage, de-energi-
ses after actuation
Relay energised by providing
operating voltage, de-ener-
gises after actuation, inverse
output signal
Relay energised, as soon as
one switch is actuated, de-
energises, when all taught-in
switches are not actuated
Latching function/impulse
function
- repress push-button S1 for 5 s until LED MD is off
- LED MD is on and LED 1 is off
- Operation mode is set back to standard
- release push-button S1
- LED MD is on and LED 1 flashes fast
RF Rx EN868-2W-RS232
Selection of the baud rate
- standard preset baud rate is 9 600 Bd
- press push-button S1 and S2
- LEDs 1, 2 and MD flash
- press push-button S1 for selection of baud rate
- LEDs B1 and B2 indicate the baud rate
- press push-button S1 to select the desired baud rate
LED B1
LED B2
Baud rate
off
off
9 600 Bd
on
off
19 200 Bd
off
on
38 400 Bd
on
on
57 600 Bd
- press push-button S1 to show the selected baud rate
- press push-button S1 and S2 to quit without changing the setting
Telegrams
All EnOcean telegrams are displayed at the serial interface.
français
Descriptif et fonctionnement
Le récepteur à deux canaux RF Rx EN868-2W-RS232 est destiné à la
commande à distance d'organes électriques par transmission radio,
sur une fréquence fixe de 868,3 MHz. Les émetteurs de commande
utilisent le protocole de communication EnOcean, à l'aide des modules
PTM et STM intégrés. La sortie du récepteur peut être pilotée par dix
émetteurs maximum par canal. Chaque émetteur doit, au préalable,
être calibré sur le récepteur par auto-apprentissage.
Montage / Raccordement
Seules des antennes compatibles sont recommandées: antenne avec
câble 2,50m et connecteur SMA, article n° 01.08.0386. L'antenne doit
être montée sur une tôle d'au moins 250 x 250mm, faisant office de
»contrepoids HF«. Respecter une distance latérale d'au moins 300mm
jusqu'à un mur ou une source parasite. Le câble d'antenne ne doit pas
être tordu ou pincé, rayon minimal de torsion > 15mm. La distance de
détection est grandement dépendante des conditions locales. Ainsi le
signal radio est fortement influé par les matériaux conducteurs. Ceci
concerne également les tôles fines, telles les feuilles d'aluminium co-
laminées des matériaux isolants. En cas de doute, procéder à un essai
de portée avec le récepteur universel EPM 300, article n° 01.08.0416.
Quelques portées typiques:
En vision directe champ libre : environ 300m
En vision directe dans un couloir : environ 30m