8. WARNINGS AND ERRORS
If an error occurs during operation, the respective error is sent by
SMS message to the number saved last.
Warnings / Errors
If a wrong command was sent
such as: 4231 A60
If the command text has no
valid values included such as:
1234 A15
Resetting GSM module
(see notice below)
There is no room sensor
connected. Please switch to
manual mode!
The room sensor lost the
connection during comfortmode
- please switch to manual mode!
Pellet hopper lid open
Door open
Not enough low pressure
No pellets
Not ignited
Flame sensor defect
Dischargemotor defect
Dischargemotor blocked
Fan defect
Not enough low pressure
(permanent)
Stove overheated
Text-message
FAILURE: code error
FAILURE: text error
FAILURE: sending SMS - resetting
GSM module
FAILURE:
no
room
sensor
available
WARNING: room sensor signal
lost - please switch to MANUAL
MODE
WARNING: pellet cover open
WARNING: door open
WARNING: not enough low
pressure
FAILURE: no pellets
FAILURE: not ignited
FAILURE: flame sensor defect
FAILURE: dischargemotor defect
FAILURE: dischargemotor blocked
FAILURE: ID fan defect
FAILURE: low pressure control
FAILURE: safety temperature
limiter
Note:
Warning messages are not sent automatically. If during an SMS
request or command a warning message is on the display of the
stove, this warning is returned by SMS. For example as: Door open.
This is not possible when you suppress your telephone number!
Note:
If the modem is forced to send, for example through information
SMS of the network operator, SMS reply to a number, it will be
restarted for security reasons after five runs and sends a notification
to the stored number:
FAILURE: sending SMS - resetting GSM module
The modem is fully operating again after the automatic reboot.
|27