9. Open the valve of the gas
cylinder
(see point 7 in section
"Instruction How to Mount the
Regulator").
10. Check for leakage.
11. Set the regulating pressure
to a suitable pressure and
open the shut off valve (if
existing).
12. Open the dispense head.
Technical data/features
This product is designed to be
compact, accurate, durable, and
safe. It is available for CO2, N2
or Mixed Gas.
This product is a non-service
product. A "intact" tamper
evident ring on the body is
showing that the regulator has
not been opened.
The pressure is adjusted with
the 4 mm allen key included in
the packaging. The included
tamper evident cap can be fitted
after pressure adjustment or
the allen key can be left on the
regulator for further adjustment.
The pressure reduction is
achieved by rotating the
adjusting screw to the working
pressure requested.
Fulfils the
requirements of Pressure
Directive 2014/68/EU
Materials fulfil the
requirements of FDA Title
21§1772600, BGA.
Regulator available in
Primary or Secondary and
serial version.
Safety Relief Valve prevents
increase of pressure in the
system.
Inlet filter (gas in) for
protection of regulator
and system from foreign
material.
Working pressure:
From 0,5 bar up to 90%
of the nominal pressure
indicated on the low-
pressure gauge.
Venting Function.
Max./min. ambient
temperature +45°C/+5°C
(working temperature min.
-40°C).
Capacity: Max. 100 l/min.
Max. inlet pressure 230 bar.

Auxiliary equipment

All pressure regulators are also
available for other pressure
MICRO-MATIC.COM
|