This battery charger should not be operated
neither by physically disabled or mentally
a ected people, nor by untrained or unskilled
people.

3.2.2. Battery

Caution:
Following safety rules must be follow-
ed for adequate protection against electrical
shock, injuries or re hazards:
Never try to charge a damaged battery.
Do not insert a dirty or wet battery into the
c
a h
g r
. r e
Never throw batteries into the waste, into re
or into water.
Do not charge a battery when the environment
temperature is below 0°C.

3.3. Charging procedure

Charge only RIVIT batteries when the environ-
ment temperature is between 0°C and 40°C.
Take the charger out of its package and
connect to mains. Check the input voltage on
the type label before connecting.
Insert the battery in the right way (pole+ to
pole+) into the charger bay. Insertion should
take place without noticeable e ort.
The charging operation starts automatically
when the battery is inserted into the charging
bay.
Function lights:
Steady green:
Battery is charged,
preserv.charge in process
Blinking green: Charging
Steady red:
Charging temperature out of range
(battery too hot or too cold)
Blinking red:
Battery is defective
Typical charging cycles:
Type
Part Number
1,3 Ah
4207600
2,6 Ah
4207700
*charging cycles may vary according to the rest capacity and the
battery temperature.

3.4. Battery handling

Use only cold batteries to obtain optimum
c
The RIVIT batteries can be charged approx.
1.000 times and reaches its maximum capacity
only after several charging cycles.
Do not insert the battery into the charger after
a e
charged (tool cannot set the rivet).
Recharge the battery after a long period of
inactivity.
Battery autonomy becoming shorter despite of
proper recharging means that the battery must
be replaced.
Keep the battery in dry and warm rooms.
The optimum operating temperature range is
10°C to 50°C.

3.5. Environmental protection

If batteries have to be replaced,
the following instructionsshould be
followed:
Bring back discarded batteries to your RIVIT
agent or to RIVIT for recycling.
Never throw away discarded batteries into
waste, re or water.