Recommendation: For inductive appliances that cause voltage spikes during
•
switching on/off — such as electrical motors, fans, vacuum cleaners, and similar
devices — an RC snubber (0.1µF / 100Ω / 1/2W / 600V AC) should be connected in
parallel with the appliance.
If you want to use the Device in dual input mode, connect the Device as shown in
•
Fig. 3 for switch inputs:
Connect both L terminals to the Live cable and the N terminal to the Neutral
cable.
Connect the common motor terminal/cable to the Neutral cable.
Connect motor direction terminals/cables to the O1 and O2 terminals.
Connect the first button/switch to the S1 terminal and the Live cable.
Connect the second button/switch to the S2 terminal and the Live cable.
LED Indicator Light
LED Indicator Light
White light on
White light off
Blue light blinks fast
Blue light blinks slowly
Blue light off
Blue light on and then off
Resetting Factory Settings
Press and hold the button on the device for 15 seconds to restore it to factory settings.
Please note that this action will erase all stored data and settings.
Description
Device powered on
Device powered off
Device being added
Connecting to the network
Connected to the network
Factory settings restored
6