Caution
Caution! Danger of electrocution – installation must be
done by a qualified electrician.
Caution! Any changes to wiring must be made only after
ensuring no voltage is present at the device terminals.
Caution! Use the device only with power grids and
appliances that meet all applicable regulations.
Caution! A short circuit in the power grid or connected
appliances may damage the device.
Caution! Do not connect the device to appliances that
exceed the specified maximum load.
Caution! Follow the provided wiring diagrams only.
Incorrect connections may cause injury or damage.
Caution! Do not install the device in locations exposed
to water or excessive humidity.
Recommendation: Use solid single-core cables with
insulation heat resistance of at least PVC T105°C.
Before installation, turn off circuit breakers and confirm
there is no voltage at the terminals using a phase meter
or multimeter.
To use the device for controlling two load circuits,
follow:
Figure 1 for AC circuits
Figure 2 for DC circuits
Caution! Use the same power supply for the two load
circuits and the Device.
For AC circuits, connect both L terminals to the Live cable
and the N terminal to the Neutral cable.
Connect the first load circuit to the O1 terminal and the
Neutral cable.
Connect the second load circuit to the O2 terminal and the
Neutral cable.
Connect the first switch to the S1 terminal and the Live
cable.
Connect the second switch to the S2 terminal and the Live cable.
For DC circuits, connect both L terminals to the Negative cable and the N terminal
to the Positive cable.
Connect the first load circuit to the O1 terminal and the Positive cable.
Connect the second load circuit to the O2 terminal and the Positive cable.
Connect the first switch to the S1 terminal and the Negative cable.
Connect the second switch to the S2 terminal and the Negative cable.