2.15.2. Marking on Rating Plate
The rating plates have the following markings:
Typ: EMD 3100-01
Mat: Ms / Ni / PVDF
Pin:
Pout: 0,5 - 10 bar
Explanation:
Manufacturer, date of manufacture 14.07. = Juli 2014). Type designation, permitted pressure
(pin). device-specific outlet pressure range (pout). Materials of pressure reducing chamber (Ms
= brass I ES =special steel, surface coating (Ni = nickel for brass housing and seat seal (PVD,
FKM/FFKM [fibre-reinforced plastic). PCTFE). Safety information and the permitted type of gas.
The valves also have a marking showing the direction of flow of the gas (inlet to Outlet marked
with an arrow) The serial number, which is specific to the device, is shown on a separate plate
in barcode 128 and in clear text.
2.15.3. MARKING OF INLET AND OUTLET
Inlet and outlet threads of PoU regulators and valves bodies are indicated with a lasered
marking:
Marking
3. WARRANTY AND LIABILITY
In general the GCE "General Purchase and Supply Conditions" will apply. These have been
available to the owner since conclusion of the contract at the latest. Claims arising from warranty
or liability are excluded in the case of personal injury or material damage if these are the result
of one or more of the following causes:
•
Improper use of the pressure unit / Usage against "Intended Use"
•
Faulty installation, startup, operation or maintenance of the pressure unit.
•
Operation of the pressure unit while safety equipment is defective or if safety and protective
devices are not fitted or not operative.
•
Non-compliance with the information in the operating instructions: Storage, installation,
startup, operation, maintenance and preparation of the pressure unit.
•
Independent structural modifications to the pressure unit.
•
The permissible supply pressures have been exceeded or outside or non-genuine seals have
been used.
•
Deficient monitoring of accessories, threaded parts and sealing parts subject to wear.
•
Repairs not carried out properly.
•
The temperature range given in the specification sheet has been exceeded or not reached
During operation or during storage.
•
Disasters caused by the action of foreign bodies and force majeure.
Attention!
pressurized parts, Service
only by authorized
40 bar
personnel.
OXYGEN
Inlet:
25/36
Outlet:
EN