3. Troubleshooting
Problem
The buoy does not fit
into the pocket.
The Velcro does not
secure properly.
The CO2 cartridge
is punctured
immediately upon
screwing it in.
The CO2 cartridge
cannot be screwed
in or only screwed in
with much difficulty.
4. Storage, care, maintenance and disposal of your RESTUBE product
Lifespan & storability
RESTUBE products are designed for long-term use to have a long lifespan and can be triggered
between 50 to 250(*) times, depending on the version. After each use, store the device outside
its packaging, in a well-ventilated area at a maximum temperature of 28°C. The maximum lifespan
of the device is 5 years from the date of purchase, provided that all the care and maintenance
instructions are followed.
If used frequently (more than once per week) or in tropical climates, the product lifespan may be
shorter. In high humidity, remove the device from its packaging. Do not put RESTUBE products on
radiators and do not dry or store them in direct sunlight.
Care
Maintain your RESTUBE product after each use. Spending five minutes on care will help ensure its
reliability and durability.
>>> Take the bladder out of its pouch and check all parts for visible damage: the pouch, bladder,
trigger, trigger cord and CO2 cartridge. None of the parts should show signs of excessive wear, rust
or damage.
>>> After use in saltwater or chlorinated water: Remove the bladder from its pouch, and rinse
both in fresh water, ensuring that the oral valve is closed and the cartridge is securely screwed in.
If the product has become particularly dirty, wash it with mild detergent or a diluted solution of lye
and rinse it with fresh water afterwards. Do not use cleaning agents containing alcohol or solvents.
>>> The bladder and its pouch should be opened and hung out to dry. Once dry, repack the system
according to the packing instructions.
Maintenance
With basic care, you will be able to maintain your undamaged RETUBE product yourself. If you have
any questions or concerns, please contact us by email at professional@restube.com.
We would be glad to conduct a check for you. You just need to cover the postage and any required
replacement parts. NOTE: Do not attempt to repair your RESTUBE product on your own!
12
Cause
The buoy is not fully
emptied.
The buoy is not folded
correctly or is improperly
positioned in the pocket.
The release lever was not
reset before screwing in
the new CO2 cartridge.
Dirt is on the thread or
trigger mechanism
Corrective action
> Fully deflate the buoy.
> Follow packaging instructions
carefully.
> Make sure the nut on the trigger
is aligned with the label displaying
the nut symbol.
> Reset the release lever.
> Clean the trigger mechanism.
(*) Restube automatic PRO: Up to 100 times