Herunterladen Inhalt Inhalt Diese Seite drucken

REV Ritter L300S241 Installationsanleitung Und Gebrauchsanweisung Seite 3

Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
LED under cabinet light
Installation instructions and instructions for use
Introduction
Dear Customer,
We'd like to thank you for purchasing our product. Please read the following operating instructions thoroughly before using this product for the first time and keep it
handy for future reference (S1).
Please check the product before use for any damage.
Proper Use
Luminaire for ceiling mounting on normally flammable surfaces in dry spaces.
Not suitable for through-wiring.
The product conforms to the appropriate European CE directives (S2).
This product conforms to the appropriate European safety standards.
The product is IP20 rated and suitable for use in dry interior spaces (S3).
General Safety Instructions
Please observe the technical specifications!
Please follow this instruction manual and keep it in a safe place!
Please pass on this instruction manual to a subsequent owner!
Not to be used by children!
Do not operate a defective product!
Must not be used in areas that represent an explosion hazard (e.g. carpentry workshop, paintshop, or similar)!
For the connection, only use regular mains sockets (230V~, 50Hz) with protective conductors of the public supply network which are easily accessible!
De-energised only when the plug is pulled out (S4)!
INSTALLATION AND CONNECTION
Power to the light must be switched off! Switch off the mains fuse!
Ensure that you do not drill through cables in the wall!
Maintain a safety distance to the surfaces to be illuminated: min. 30 cm!
CLEANING
Remove the mains plug from the mains socket (S5).
Wipe with a damp cloth.
Do not use chemicals!
REPAIRING
Replace any damaged protective panels immediately (S6).
The light does not contain any components which can be repaired. Dispose of the light in accordance with local regulations. Do not dispose of it in the household
waste!
The light source in this light is not replaceable. If the light source needs to be replaced (i.e., at the end of its service life), then the entire light must be replaced.
TECHNICAL DATA
Model
Article
L300S241
V300
L600S241
V600
L800S241
V800
L300S33
Z300
L600S33
Z600
General information
These products contain a light source of energy efficiency class F
Colour temperature: 3000K
Colour rendering index (Ra/CRI): >80
Beam angle: 120°
Connection cable: approx. 1.45 m, H03VVH2-F 2x 0.75mm²
IP rating: IP20 (only use in dry indoor spaces)
Protection class: II (connection without protective conductor) (S7)
Application temperature range: 0°C – +35°C
LED service life: 20000h
WEEE-reference of disposal
In accordance with European defaults used electrical and electronics devices may no more be given to the unsorted waste. The symbol of the waste bin on wheels
refers to the necessity of separate collection. Please help with environmental protection and see to it that this device is given to the for this purpose designated
systems of waste sorting if you do not use it any longer. DIRECTIVE 2012/19/EU of the EUROPEAN PARLIAMENT AND OF the COUNCIL of 4 July 2012 on waste
electrical and electronic equipment (WEEE). (S8)
LED
LED
1
Light source not
Control gear not interchangeable
1
2
interchangeable!
(ballasts, power supply units, etc.)!
Output
Nominal values
4W LED
230V~, 50Hz, 0,023A
8W LED
230V~, 50Hz, 0,042A
12W LED
230V~, 50Hz, 0,072A
4W LED
230V~, 50Hz, 0,029A
8W LED
230V~, 50Hz, 0,048A
2
Luminous flux
Luminous efficacy
320lm
80lm/W
600lm
75lm/W
1020lm
85lm/W
340lm
85lm/W
600lm
75lm/W
GB
Inhaltsverzeichnis
loading

Diese Anleitung auch für:

L600s241L800s241L300s33L600s33