7 7 7 7
CLEANING AND MAINTENANCE
Disconnect from mains before starting maintenance operation!
We recommend a frequent cleaning of the device. Please use a moist, lint-
free cloth. Never use alcohol or solvents!
There are no serviceable parts inside the device. If defective, please dispose
of the unusable LED strip in accordance with the current legal regulations.
Should you have further questions, please contact your dealer.
...............................................................................................................................................
8 8 8 8
TECHNICAL SPECIFICATIONS
Model
Power supply:
Power consumption:
LED strip:
Watts per meter/total:
Battery/remote:
Protection grade:
LED type:
Number of LEDs:
Serial connection:
Cutting mark:
Dimensions:
Weight:
www.eurolite.de
DANGER TO LIFE!
50532000 / 1.5 m
100-240 V AC, 50/60 Hz ~
via supplied PSU
12 W
12 V DC, 0.75 A
7.2 W/10.8 W
45
Ø 10 mm x 1500 mm
70 g
21
50532010 / 5 m
12 V DC, 3 A
7.2 W/36 W
1 x CR 2025
IP 68
SMD 5050
yes
every 100 mm
Ø 10 mm x 5000 mm
40 W
150
190 g