Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis
After the boiling process is finished, the thermopot will auto-
matically switch to the keep warm mode, and the keep warm
mode indicator (22) will appear on the display (3), and the indi-
cator (19) will glow constantly.
Note: The thermopot will maintain the temperature at 85 °С by
default.
Heating temperature
You can use the button (14) to select the heating temperature
within the range from 45 °С to 95 °С with the step 5 °С.
Note: If the selected temperature is lower than the temperature
in the thermopot, then the water in the thermopot will first cool
down to the set temperature, after that the selected temperature
will be maintained. When the water temperature in the thermopot
drops below the set temperature by more than 5 degrees, the
thermopot will switch to heating mode.
Cooling function
You can speed up the cooling of the water in the thermopot to the
set temperature by switching the cooling mode on by pressing
the button (12), the indicator (18) will constantly be displayed on
the display (3). Upon reaching the set temperature, the thermopot
will switch to the keep warm mode.
Water type
There are 2 modes in the thermopot depending on the water
type: tap water and drinking water. You can select the modes
with the button (13). Depending on the type of water, the dis-
play (3) will show the corresponding indicator: tap water (19)
or drinking water (21).
When choosing tap water, the water is boiled first, after which
the thermopot switches to the keep warm mode.
When choosing drinking water, the water is heated to the preset
temperature, followed by maintaining the temperature.
Water dispensing
Place a suitable bowl on the tray (1), press the button (15), the
corresponding indicator (23) will light up on the display, then
press and hold the water supply button (16), the indicator (20)
will appear on the display (3).
Note: If, after unlocking, no action is taken for about 10 seconds,
the lock will be switched on again automatically and the corre-
sponding indicator (23) will go out.
Attention! Be careful when pouring out water to avoid burns
by hot water.
To switch the thermopot off, press and hold the button (13) for
more than 3 seconds.
Note: To switch on again the thermopot connected to the mains,
press and hold the button (13) for more than 3 seconds.
To disconnect the thermopot from the mains, disconnect the
power plug (11) from the mains socket.
Open the thermopot lid (8) and wait until it cools down com-
pletely, drain the water, close the lid (8) and put the thermopot
away for storage.
Attention! Be careful when pouring out water to avoid burns
by hot water.
Overheating protection
If you accidentally switch the thermopot on without water, the
automatic thermal switch will work, and the symbols «E4» will
appear on the display (3).
In this case unplug the thermopot and let it cool down for
10-20 minutes, then fill it with water, and switch the thermopot
on, the unit will operate in normal mode.

CLEANING AND CARE

Before cleaning, disconnect the thermopot from the mains,
pour out water and let the thermopot cool down completely.
Open the lid (8) and carefully tilting the thermopot drain the
remaining water, then close the lid (8).
Clean the outer surface of the thermopot with a slightly damp
cloth and then wipe it dry.
Use neutral detergents to remove dirt; do not use metal
brushes, abrasive detergents and solvents.
Do not immerse the thermopot and the power cord into water
and other liquids.
Do not wash the thermopot in a dishwashing machine.
Stains on the inner surface of the thermopot
The inner surface of the metal flask may change its color under
the influence of different water impurities.
You can remove the stains with citric acid or vinegar.
To remove the flavour of citric acid or vinegar, boil water and
pour it out.
Repeat this procedure until the smell and taste vanish com-
pletely.
Descaling
Scale, appearing inside the metal flask, causes the heating
element overheating and malfunction. Burning of the heat-
ing element caused by the scale in the thermopot is not cov-
ered by warranty.
To remove the scale fill the thermopot with a mixture of one
part ordinary vinegar and two parts water up to the maximal
level mark «FULL».
Insert the power cord (11) connector into the socket (10) on
the thermopot body, and the power cord (11) plug into the
mains socket.
11
ENGLISH
Inhaltsverzeichnis
loading

Inhaltsverzeichnis