CONNECTORS & LEDs
RJ45 Port:
Power over Ethernet IEEE802.3af/at (PoE+), Mode B
RJ45 Port
Pin
Signal
PoE
Pin
1
BI_DA+
2
BI_DA-
87654321
3
BI_DB+
4
BI_DC+
VCC+
PoE Budget
Port 1-8
30W / Port
240W@48V 120W@24V
Port 9+10
-
-
Status LEDs:
LINK / Activity LED
PoE LED
LED Name
Color
LED Function
On:
Linked
L/A
Green
Flashing:
Data Transmission
On:
PoE is activated
PoE
Yellow
Flashing:
Power Device (PD) detected
Off:
No (PD) device connected
On:
Powered
Power
Green
Off:
Power off
12V to 48V T-Block:
ATTENTION!
Please pay attention to the correct polarity!
Never connect the power supply to the terminal block
while it is switched on!
V- V+
V- V+
Redundant power supply possible to reduce operational failure.
Both power supplies must use the same voltage!
5
HARDWARE INSTALLATION
Please read the following installation instructions.
1.
Install the EX-62026POE on a mounting rail using the DIN-Rail kit.
Signal
PoE
5
BI_DC-
VCC+
6
BI_DB-
7
BI_DD+
VCC-
8
BI_DD-
VCC-
Total max.
70W@12V
-
-
2.
Connect the power connector of the optionally available power supply to the terminal block
and turn on the power supply.
3.
When the power is turned on, the PWR indicator lights up. If the indicator is not lit, check
for proper connection to the power supply.
4.
Connect your network devices to the switch using a network cable.
PWR LED
5.
If all cables are connected correctly, the indicators light according to the port status of the
LEDs (page 5).
TECHNICAL NOTE
Procedure for STP Cable Grounding
When using shielded cables to connect two Ethernet devices, a ground loop may occur if the
shielding on the cables generates an additional grounding connection path. This can cause
ground current to flow through to the Ethernet ports and damage the devices. If it is necessary
to use shielded cables, we recommend using a metallic RJ45 connector on one end and a non-
metallic connector on the other end. Alternatively, a patch panel can be used in between the
two devices to prevent ground loops from occurring.
For connections over short distances (e.g., between two devices installed in the same cabinet),
both ends of the shielded cable can be referenced to the same grounding point. Therefore, in
this case, it is acceptable to use a shielded cable with metallic RJ45 connectors on both
devices.
CLEANING
To clean the unit, use only a dry, lint-free cloth and apply light pressure to remove dirt. Take
care not to leave any fibres of the cloth in the connectors.
Never use a damp or wet cloth for cleaning!
Germany:
EXSYS Vertriebs GmbH
Industriestrasse 8
61449 Steinbach
www.exsys.de
The DIN-Rail Kit is pre-assembled
on the rear side
Switzerland:
Italy:
EXSYS Vertriebs GmbH
EXSYS Italia Srl
Dübendorfstrasse 17
Via Belvedere, 45/B
8602 Wangen
I-22100 Como
www.exsys.ch
www.exsys.it
6
EX-62026PoE
Anleitung
Anleitung
Vers. 1.0 / 20.07.25
AUFBAU
Betriebs LED
2x RJ45
8x RJ45
PoE / Status-LEDs
100/1000 Mbit/s
Gigabit PoE
BESCHREIBUNG & TECHNISCHE DATEN
Der extrem kompakte industrietaugliche 10-Port Gigabit PoE-Switch EX-62026PoE bietet trotz
seiner äusserst geringen Aussenmaße volle Gigabit Leistung an allen 10 Ports. An acht
Downlink-Ports stehen jeweils bis zu 30W für den Anschluss von PoE Power Devices (PD) wie
z.B. IP-Kameras oder IP-Telefone zur Verfügung. Dank dem robusten Metallgehäuse und dem
erweiterten Betriebstemperaturbereich von -40°C bis 80°C ist er für eine Vielzahl von
Anwendungen auch in rauen Umgebungen geeignet. Die Stromversorgung erfolgt über den
Terminal Block (12-48 VDC) und kann zur Verminderungen von Betriebsausfällen auch
redundant erfolgen. Der EX-62026PoE unterstützt Auto-MDI/MDI-X und Auto-Negotation.
Kompatibilität:
Gigabit Ethernet 10/100/1000Base-T
PoE:
IEEE 802.3af/at (PoE+), Mode/Alternative B
Betriebssysteme:
Alle Betriebssysteme
Anschlüsse:
10x RJ45-Buchse (8x PoE+), 1x Terminal Block 12~48VDC
Lieferumfang:
EX-62026PoE, DIN-Rail Kit, Wandmontagebügel, Anleitung
ACHTUNG!
Bei
geerdetem
Minuspol
unbedingt den Technischen Hinweis auf Seite 3
beachten.
1
12-48V T-Block für optional
erhältliches Netzteil
der
Stromversorgung