Step 3. Ground

If available, the chassis ground lug should be connected to a ground point such as a vehicle
chassis or boat grounding system. In fixed locations, connect the ground lug to earth ground. The
connections to ground must be tight and against bare metal. Grounding is highly recommended
for both when using the inverter in a mobile application, such as an RV, or in a building.
Empfohlene Komponenten
Grounding Cable
Grounding

Step 4. DC Wiring

Be careful of the positive and negative poles. Reversing the poles might cause permanent
damage to the inverter and will void the warranty.
For your safety, it is recommended to use a 150A/250A battery fuse.
The inverter is suitable for 24V battery bank systems ONLY. Not following the minimum DC
requirement will cause irreversible damage to the device.
The input terminals of the inverters are embedded with large capacitors. The input circuit
is completed once the terminals are connected to both positive and negative wires. This
commences drawing a heavy current momentarily. As a result, there may be a sparking
occurring even if the inverter is in the off position. To minimize sparking, it is recommended
that you should choose an appropriate sized wire feeding into the inverters and/or install
an external fuse leading into the inverter.
Grounding Cable (12 AWG)