Admissible garage door types
◆ swing out standard up-and-over doors
◆ sectional doors
The doors must move smoothly and comply with the regulations of the
following standards: EN 13241 / EN 12453 and EN 12604.
Permitted garage door dimensions
Permitted door leaf surface:
(for easy to move up-and-over doors and
sectional doors)
Maximum infill weight for up-and-over doors: 7 kg/m
Item no. RP-S4-550N-1/RP-S4-550N-3/RP-S4-550N-5
Maximum travel of the rail (travel path):
Maximum door height for up-and-over doors: 2125 mm (2375 mm)*
Maximum door height for sectional doors:
*
The dimensions given depend upon the installation of the header bracket
(please refer to page 51). The dimensions in brackets apply only for
ceiling mounting.
Inadmissible types of garage door
Doors which require tilting and rotating movements may
not be operated with the RolloPort S4 garage door opener.
44
10.5 m
2
2
Item no. RP-S4-550N-2/RP-S4-550N-4
Maximum travel of the rail (travel path):
2150 mm (2490 mm)*
Maximum door height for up-and-over doors: 2625 mm (2750 mm)*
2000 mm (2250 mm)*
Maximum door height for sectional doors:
Up-and-over doors
Non swinging out retractable
up-and-over door
EN
Ceiling sectional doors
2680 mm (3020 mm)*
2500 mm (2750 mm)*