7. DELETING A USER FINGER

Biohandle provides a »delete user finger« function without
employing a visual database (e.g. a fingerprint template can
not be connected to the user's name, surname or other vital
data). This means that the user who has to be deleted must be
present, but also that the user's identity cannot be revealed to
a third party. User finger delete selection is done via a positive
match of swiped finger. Only one finger of a user can be dele-
ted at one time, not all fingers of the user at the same time! If
same finger was enrolled more than one time, procedure must
be repeated with the same finger as many times as it was enro-
lled. Please check Administrators and users list to check how
many fingers of the user, which should be deleted, are enrolled
and how many times same finger was enrolled.
How to delete a user?
Check the Administrators and users list to see which fingers of
the user, which should be deleted, are enrolled and inform user
which fingers he/she must press.
The lower button on the Biohandle unit should be pressed for
5 seconds whereupon the blue LED will start flashing.
An administrator presses his/her finger on the sensor once.
When he/she is identified, the green LED will flash and the
buzzer will buzz one time.
The red and green LEDs will flash alternately. Then the user
presses his/her finger on the sensor once. When the user is
identified, the red and green LEDs flash and the buzzer will
buzz three times. The user finger has been successfully deleted
from the system.
8. DELETE ALL (USERS AND ADMINISTRATORS)
By performing this function all existing templates in the data-
base are deleted. After this procedure the device database will
be empty and the next three fingerprints enrolled will have
administrator rights again.
This function is used when the Biohandle or the place where it
is installed should get a new owner or when there is a need to
change the administrator.
To prevent that delete all function will be performed by mista-
ke, 2 authentications by administrator are required.
How to delete all?
Press the upper and lower button together for a period of 10
seconds whereupon the blue and red LEDs will flash alterna-
tely.
The administrator then presses his/her finger once. Identifica-
tion is confirmed when the green LED flashes and the buzzer
buzzes one time.
The blue and red LEDs will flash alternately again. The admini-
strator then presses his/her finger once again. Identification is
confirmed when the green LED flashes and the buzzer buzzes
at the same time.
The red and blue LEDs will flash and the buzzer will buzz five
times simultaneously. All fingerprint templates will then have
been deleted.
IMPORTANT:
When performing the 'Delete all' function it is necessary that
the administrator confirms it twice. At any time during the
execution of the 'Delete all' function, the function can be
stopped with time out.
FACTORY RESET
How to delete all if administrator is not available anymore? The-
re is a black pushbutton on the internal unit, which is located
inside the door, beside the motor lock. The lock must be dismo-
unted to access the button. Press the button for 30 s and after
this time fingerprint data base is deleted. After performing the
factory reset, all fingerprints in the database are erased.