4.2 Special conditions for use in
areas of Zone 0 or 21
1. The Lite-Ex LED 30 is only certified
and permitted for used in Zone 0 or 21
providing it is secured to the user with
the provided lanyard/wrist strap.
2. The torch unit should be prevented
from being dropped.
3. The torch unit must not be left any-
where or stored in Zones 0 or 21.
4.3 Special conditions in dusty
Ex-areas
1. After each change of batteries, the
torch must be blown out or internally
cleaned with a suitable device.
2. The sealing ring must be checked for
any deterioration or damage.
5. Ex-Data
EC Certificate of Conformity No.:
Ex-Designation:
Approved for Zone 2, 1and 0; equipment
group II, gas group IIC;
explosive gases, vapours or fog,
temperature class T4.
Approved for Zone 22 and 21; equipment
group II, explosive dusts; T90°C
Report Job Identification No.: 3 0 1 5 5 6 2
FM-Certification:
I.S. Class I Division 1 Group A-D T4
6. Technical Data
Ambient operating
temperature Ta:
Storage temperature:
Batteries / power supply: 3 x LR1 as per IEC
(see table of approved battery types)
ZELM 02 ATEX 0104
II 1 G EEx ia IIC T4
II 2 D T90°C IP 52
-20 ... +50°C
-20 ... +60°C
16
Table of approved batter y types
Manufacturer
Duracell
Varta
Eveready Battery
Company, Inc.
Battery life:
Dimensions:
Weight:
EC-Designation:
Light source:
Type:
Life expectancy:
7. Use and Application /
Operating Instructions
Before use, please read these
operating instructions very carefully
in order to familiarise yourself with
your Lite-Ex LED 30.
For you own safety and information,
please read the following instructions.
7.1 Commissioning
In order to be able to use the torch in the
Ex-hazardous area, you must first check
that the base cap is tightly fastened and
that the safety screw is securely and
completely fitted. After checking these
points the torch can be used in the Ex-
hazardous areas – operation is by
pressing the switch.The torch is supplied
with factory fitted batteries.
7.2 Battery Replacement
When the brightness is no longer satis-
factory and the batteries are to be
replaced, it is strongly recommended
that all 3 batteries should be replaced as
a set. When replacing the batteries
Type
Alkaline MN9100
Electronics 4001
Energizer E90
approx. 80 h (continuous use)
ø
140 x 26 mm (l x
)
approx. 160g (with batteries)
0102
Gallium-Nitrit-LED
(NSPW500BS)
100.000 operating hours
17