1. Thank you for using Our company's Wireless off Bed zoning pre-alarm system.
Please read the user manual carefully for your first use and keep it for future
Pressure Pad
For : Chairs
reference.
CALL
2. The system unit is small in size and easy to use, with multiple functions such
as sound and light warning/vibration reminder /SOS emergency help, bed
alarm/near bed warning, etc., which can be applied to the elderly or people
(Optional)
with mobility difficulties in homes, nursing homes, hospitals and other places.
Pressure Pad
For : 636
Wheelchair assistance.
3. System unit AA*2 battery/pressure pad sensor CR2477*2 battery/Emergency
button CR2032*1 Battery operation, low power consumption, standby time up
to one year, with low power reminder function.
Sensor
Sensor
Sensor
Sensor
1
2
3
4
4. System alarm main unit : High volume + vibration / low volume + vibration /
only vibration ,multiple modes are optional, press the MODE key to set the
MODE
LEARN
RESET
mode you need.
CALL
Pressure pad
sensor
connector
the sensor area of the sensor LED lighten ( Go on forever ).
Press the
5. Learn code pairing and deletion
Reset key twice to release the current alarm, and the main unit enters the
a. The product has learn code paired when left factory ,if you need to change the
working standby state again. The wireless distance between the alarm main
pairing SENSOR area or increase the pairing use (1main unit can be paired
unit and the pressure pad sensor is about 40 to 50 meters.
with 4 sensors), long press the LEARN key for
mode, SENSOR 1 LED flashing, indicating that the area can be paired.Trigger
the SENSOR to be paired (the pressure pad SENSOR can press the pressure
pad with the palm and then loose the palm, and the CALL button can press the
Sensor
Sensor
Sensor
Sensor
1
2
3
4
CALL key), and hear the Bi sound of the main unit. SENSOR 1 If the LED is
40~50
meters
long on, the pairing is successful. For example, If the SENSOR 1 LED is long
MODE
LEARN
RESET
on, it indicates that there is pairing in the area.Tap the LEARN key to select the
SENSOR 1-4 pairing area and repeat the SENSOR 1 pairing operation for
pairing. Press the RESET key or no operation for 30 seconds to exit the
learning code pairing mode.
b. Delete the SENSOR pairing. At the same time, Press the MODE+RESET key
for 5 seconds to enter the deletion mode.and the SENSOR 1 LED will light
long on(press the LEARN key to recycle select the existing SENSOR 1-4
for deletion), and hold down the LEARN.
Pressure Pad sensor
key for 3 seconds to delete the pairing in the SENSOR 1 area.
Wireless RF about 40-50 meters
SENSOR 1 LED Blinking indicates that the SENSOR 1 is successfully deleted.
SENSOR 2-4 can repeat SENSOR 1 operation. Press the RESET key or do not
Sensor
Sensor
Sensor
Sensor
perform any operation for 30 seconds to exit the deletion mode.
1
2
3
4
MODE
LEARN
RESET
b. Pre-warning testing (For 636) : The simulated human body lies on the pressure
1. The surface material of the pressure pad is PVC. Please don't direct touch with
pad sideways or moves to the warning area at both ends of the pressure pad
human skin when using it. You can put the pressure pad under the bed sheet
placed on the edge of the bed. In that case, the pressure pad sensor detects
or thin cushion and test whether it can work normally.
that the human body will falling from the bed is in danger and immediately
2. Alarm main unit. The red LED indication when the pressure pad sensor battery
is low, and the LED light dimms when the button battery is low. Please replace
sends a signal to activate the alarm main unit to prompt family members or
caregivers to adjust the bed position of the caregivered to the safe area in the
the battery in time to ensure normal use.
3. If the product is not used for a long time, please take out the battery to avoid
center of the bed.
c. Emergency CALL test: press the call button and activate the alarm host
to
battery leakage and damage to the device.
4. This product is an electronic safety auxiliary product, and users must confirm
prompt family members or caregivers to help .
the necessary reliability according to the usage properties.
4. Alarm mode/volume setting:Tap the MODE key repeatedly to set the mode
5. If you have any questions during the use of the product, please contact with
and volume you want, high volume + vibration/Low volume + Vibration/Vibra-
tion mode only.
local distributor.
148mm
740mm
Working/Low
power LED
indication
Sensor 1-4 view
trigger LED
Sensor
Sensor
Sensor
Sensor
indication
1
2
3
4
MODE
MODE
LEARN
RESET
LEARN
RESET
Buzzer
Lanyard buckle
(Optional)
Working/Low power LED
indication
Working-Low
power LED
indication
N.W/
LED
Pressure Pad
Pressure pad N.W/single-off
36cm x 36cm (for chairs)
3
5
seconds to enter the pairing
740mm
(正反面印刷折风琴式)
Warning one side zone
Warning area on both sides
Power
on/ off
Pressure pad center
Get out of bed alarm sensing area
Back clip
For 636
90cm x 25cm (for bed)
1. Start the system main unit. Transmit sensor.Call button battery cover, load the
battery according to the battery +/- polarity mark, (Note: AA*2 Pcs alkaline
battery is suitable for the alarm main unit, AAA * 2PCS for 636S small
transmitter, CR2477*2 battery is suitable for the pressure pad sensor,
CR2032*1 battery is suitable for the Call button), the main unit power
ON/OFF switch is on right side , Set transmit sensor Single / Double and
N.W switch option as required.
CALL
Wristband call
button(
)
Optional
CALL
Call button
610-63601-000R
CR2032
2. System main unit and sensors. The Call button (
) has been paired in
Optional
the factory, the sensor pressure pad is placed flat on the bed or wheelchair,
the small bag equipped with the transmitter is hung on the edge of the bed or
wheelchair, and the optimal position of the pressure pad is adjusted according
to the position of the human body lying or sitting (suggest that the pressure
pad be placed flat on the shoulders or under the hip of the human body). Set
the N.W/Single/Double switch option of the pressure pad sensor according
to the need of use (N.W indicates that both sides are off,Single represents
only the pre-warning area near one end of the transmitter,Double represents
the pre-warning area at both ends of the pressure pad, when the human
gravity pressure is placed in the pre-warning area, the alarm main unit will
immediately sound alarm).
Pressure Pad
CR2477
CR2477
3 Leave bed testing:
a. simulate the human body lying or sitting on the pressure pad and then leave,
the pressure pad Sensor immediately sends a signal (Model 636 pressure pad
sensor delay 3 seconds), activates the alarm to sound alarm or vibration while