EN
Troubleshooting
Common problems
There is no steam and
the indicator is not on
The noise in the steam-
guide tube is loud and
the amount of steam
that can emit is small
The ironing head leaks
The place where the
steam-guide tube is
connected with the host
leaks
The water in the water
tanks flows out
There is hot steam in
the water tank
The amount of steam is
small
There is no steam but
the indicator is on
There is no steam
The output of the steam
is irregular
The ironing brush drips The steam in the steam-guide tube
Cause
No power supply is connected
The temperature controller or the
thermal protection is damaged
The internal conductor falls off
The steam-guide tube is bent to be
lower than the horizontal line for
ironing
The ironing brush is broken
Flatly operate
Whether the seal ring is aging
Whether the connection is loose
The water tank is broken or there is a
hole in it
Whether the water pipe is blocked
Whether the voltage is too low
Whether the tube is blocked by scale
There is no water in the water tank
The aluminum heating element is
burnt
The internal components are of
failure
There is precipitate
The steam in the steam-guide tube
condenses
The steam condenses in the steam-
guide tube or ironing brush
condenses
Plug the plug into a power outlet
Ask a professional to check and
Ask a professional to check and
Raise the steam-guide tube to allow
the condensate to flow back into the
Replace the ironing brush
Operate vertically up and down
Replace the seal ring
Tighten the steam-guide tube
Replace the water tank
Remove dirt and plugs
It might be during the peak of
electricity consumption
Whether there is a high-power
electrical appliance being used. Use
it again after turning off the high-
power electrical appliance and
waiting until the voltage is stable
Use environmentally-friendly
Ask a professional to check and
Raise the vertical steam-guide tube
of the ironing brush so that the
condensate can flow back to the
aluminum heating element
Raise the vertical steam-guide tube
of the ironing brush so that the
condensate can flow back to the
aluminum heating element
Raise the vertical steam-guide tube
of the ironing brush so that the
condensate can flow back to the
aluminum heating element
7
Solution
repair
repair
machine
connections
cleaners
repair