Herunterladen Inhalt Inhalt Diese Seite drucken

Installation - JUNO JDA 5330 Montage- Und Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für JDA 5330:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

View of the hood - Fig. 1
1) Motor speed switch
2) Light switch
3) Extractable drawer
4) Metal grease filter
5) Cooking surface lighting
Use
The hood may be used in 2 ways:
External exhausting system
The air is expelled outside by means of
a pipe to be connected to the coupling
flange A (fig. 2).
Connecting the exhausting pipe
The coupling ring A has a diameter of
120mm.
We suggest to use Ø 120 mm exhausting
pipe.
Recycling version (filtering)
The air is purified by means of a carbon filter
and then returned to the room.
The active carbon filter can be ordered from
the supplier.
To install the filter, proceed as follow:
a. Remove the pull-out drawer completely.
b. Press the side handles (F) towards the
opposite side and remove the filters.
c. Fit the filter into its seat B and fix with the
two hooks C (fig. 3).
The filtered air is discharged above the top
cabinet.
The baffle plate D (fig. 2) can be fitted to the
outlet hole using the screws supplied.

Installation

When installed, the hood must be not less
than 43 cm. above electric burners or 65
cm. above gas or mixed-fuel burners.
Warning!
— The hood cannot be connected to flues of
other appliances that run on energy
sources other than electricity.
— When the hood is used at the same time of
other appliances that run on energy
sources other than electricity, provision
must be made for an adequate supply of
air.
— No food must be cooked flambé
underneath the hood.
The use of an unprotected flame is
dangerous for the filters and could cause
fires.
Therefore, never use an open flame under
the hood. When frying foods, never leave
the pan alone because the cooking oil
could flare up.
— Please, keep to the provisions of official
directives regarding the question of fume
discharge.
— The manufacturers refuse to accept any
responsibility for damage to the hood or its
catching on fire because of failure to
observe the above instructions.
Suggestions for the installation and
use of the hood
— The horizontal sections of the pipe must
be slanted slightly downwards (about 10%)
to ensure the condensed vapour not to
come back on the motor of the hood.
— The best performance of the unit is obtained
in the exhaust mode, therefore in the limits
of the possibilities it is advised to use the
external exhaust (suction) type.
— The best performances are obtained with
short pipes (max. 4 m) and with few curves.
Electric connection
Before completing any connection, make
sure the house voltage corresponds with
the voltage indicated on the label affixed
inside the hood.
The hood is supplied with a standard plug;
connect it to a correspondingly standard
socket.
In the case is intended to connect the
appliance permanently to the mains after
having removed the plug supplied, must be
fitted a two-pole switch conforming to
regulations with an opening distance
between contacts of not less than 3mm.
The manufacturers are not liable for any
problems caused by the user's failure to
observe the above instructions.
7

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis