2.10.1 Residual risks
EN
There will always be residual risks even if you operate the
product in accordance to the instructions.
SV
The following hazards can occur in connection with the
type and design of this power tool:
NO
● Hearing damage if ear protection is not worn.
● Health injuries as a result from the effect of vibration
on the hands and arms when the product is used over
PL
a long period of time or when it is not used and
maintained correctly.
DE
3
Operation
3.1
To attach and remove a battery
FI
Caution! Make sure that the battery is correctly
attached. If the battery become loose, it can cause
FR
personal injury.
NL
Caution! Do not force the battery in place. If it is
not easy to attach, it is not correctly aligned.
3.1.1 To attach a battery
Figure 2
1
Align the battery to the slots in the casing.
2
Push the battery until it clicks into place.
3.1.2 To remove a battery
1
Push the button on the front of the battery.
2
Pull the battery out from the battery port.
3.2 To attach and use the different
nozzles
3.2.1 To use the high volume nozzle
● The high volume nozzle is used to inflate large items
for example mattresses. The nozzle can also be use to
blow clean work surfaces
Figure 3
1
Put the wide end of the high volume nozzle on the
inflation port of the product.
2
Turn the nozzle anticlockwise to lock it in place.
10
3.2.2 To use the narrow nozzle
● The narrow nozzle is used to inflate small items for
example footballs or beach toys.
Figure 3
1
Attach the high volume nozzle first.
2
Put the narrow nozzle over the top of the high
volume nozzle and push it in place.
3.3 To operate the product
Warning! Explosion risk! Monitor the item to be
inflated.
Caution! Do not cover the deflation port or
the nozzle, it can cause overheating and damage the
product.
Note! The product can inflate items up to a pressure of
maximum 0.03 bar. Do not inflate to a higher pressure
than specified for the item to be inflated.
3.3.1 To inflate an item
Figure 4–5
1
Put the nozzle into the air opening on the deflated
item.
2
Push and release the trigger to start the product.
Note! Monitor the pressure with a pressure gauge during
inflation to prevent over-inflation.
3
Push and release the trigger to stop the product.
3.3.2 To deflate an item
Figure 6
1
Open the deflation port on the top of the product
and attach the high volume nozzle.
2
Put the nozzle into the air opening of the inflated
item.
3
Push and release the trigger to start the product.
4
When the item is deflated, push and release the
trigger to stop the product.
5
Remove the high volume nozzle and close the
inflation valve.