CONTROLLER STATE TABLE

Affichage
St-by
FLO
AL10 / AL11
AL15 / AL16
AL18
AL17
AL7 / AL8
AL3
AL4
AL5
AL1
AL2
AL6
AL9
AL14
AL19 / AL20
AL21 / AL22 /
AL23 / AL24 /
AL25
Explanation
Stand-by
No water flow or the flow
switch doesn't detect the
water flow
HP error
Too much temperature
difference between water
in and water out.
Comp. Out temp. Too high
Low temp protection in
cooling mode
Communication error
Probe error (Water in)
Probe error (Water out)
Probe error (coil.)
Probe error (comp. out)
Probe error (comp. in)
Probe error (ambiance)
Fan error
Outdoor temperature too
low
Power supply problem
Electronic/overheating
protection
Check
- Check if filtration pump is
working.
- Check by-pass setting.
- Check water flow switch
position.
Check electrical connection
between controller and elec-
tronic card inside the ma-
chine.
Check probe connection.
Check fan connection.
Outdoor temp is below -3
Ask an electrician specialist to
check power supply.
Stop the power supply for 5 to
10 minutes, check that air flow
is not blocked, turn ON power
supply
- 30 -
Solution (if no re-
set)
Contact your seller
Wait for the outdoor
temperature to in-
crease.
Contact your seller
Inhaltsverzeichnis
loading

Inhaltsverzeichnis