The power supply is suitable for operating the device and has an earthing connection.
•
The plug (as necessary) adapts to the plug hole.
•
If the power cord is damaged, it should imperatively be replaced by the manufacturer, a technician or a per-
son qualified to ensure safety.
WARNINGS RELATING TO DEVICES CONTAINING A COOLANT:
•
The coolant R32 is a coolant of category A2L, which is considered as potentially flammable.
•
Do not release R32 fluid into the atmosphere. This fluid is a greenhouse effect fluorinated gas, covered by the
Kyoto Protocol, with a global warming potential (GWP) = 675 for R32.
•
The device must be stored in a well-ventilated place and kept away from flames.
•
Install the unit outdoors. Do not install the unit indoors or in an outdoor area that is closed and poorly venti-
lated.
•
To comply with the relevant standards and regulations in terms of the environment and installation proce-
dures, and in particular with decree Nº 2015-1790 and/ or European regulation EU 517/2014, a search for leaks
of the cooling circuit must be conducted at least once a year. This operation should be carried out by a certi-
fied specialist of cooling devices.
•
Please keep and transmit these documents for reference throughout the lifespan of the device.
- 21 -