perature. It should therefore be adjusted:
When the pump is started, and the water is cold;
During the rise of temperature;
When the desired temperature has been reached.
There should not be any reason to subsequently adjust the flow. An occasional reading of the pressure
gauge to ensure everything is operating normally and the flow remains unchanged is generally suffi-
cient.

GENERAL USE

Water quality (standard):
The water quality standards must respect the following norms:
Chlorine concentration less than 2.5 ppm
pH between 6.9 and 8
In case of sudden chlorination, isolate the heat pump by shutting the inlet and outlet valves of the
device, and reset them to their initial positions after treatment.
Rise in temperature :
As soon as you want to put your pool into service at the beginning of the season:
• First isolate your heat pump from the filtration circuit:
• Close the upstream and downstream valves of the bypass.
• Fully open the adjusting valve.
• Carry out all the usual initial operations (filling, treatment, washing the filter, etc.).
• Turn on the filtration pump.
• Turn on the heat pump, set the temperature, open the valves and adjust the water flow.
• Cover the pelvis with isothermal cover.
• Allow the filtration pump and heat pump to run continuously until the desired temperature is reached
(2 days to 1 week depending on climatic and geographical conditions).
Remember to adjust the flow rate during and at the end of the temperature rise.
The temperature rise time depends heavily on the exposure of the pool to the wind, sun and the nature
of its environment.

Maintaining the temperature:

Once the desired temperature has been reached, you can set the daily filtration time according to
your habits (8 to 10 hours per day minimum during the season).
The heat pump will start automátically whenever necessary. The minimum operating time varies
based on the time of use, please contact your distributor for further information.
If you notice the water temperature of the pool is falling, despite the device operating continuously,
increase the daily filtration time.
Do not forget to cover the pool with an insulated cover when you are not using it, to limit heat losses.
IMPORTANT: a swimming pool without a cover will lose 4 times more energy than the same pool
with a cover. The choice of the heat pump should always take into account the presence of a tarpau-
lin, a rolling shutter, or any other type of protection of the pool when it is not being used.