*In rare cases – usually happens when inflate the spa around 0°C/39°F, the auto-inflation will stop before reaching the required pressure. This is
because the inflation takes too long that it reaches the time limitation set to prevent the spa from over-inflation. Simply press Bubble and Up button again
will reactivate the auto-inflation.
Heating and Heat Preservation
In cold weather, heating the water up will take much more time. It is suggested to:
●
Fill the spa tub with lukewarm water (not higher than 40°C / 104°F) to get it heated it more quickly.
●
Use ground mat and inflatable bladder for better heat preservation effect.
●
When the outdoor temperature is below 4°C(39°F), even when not using the spa, as long as it is filled with water, the heater should always be turned on
(or put the spa in stand-by mode) to prevent water from freezing.
●
Your spa is equipped with an Anti-icing System. Put the spa in stand-by mode, when the water temperature falls below 1°C/33.8°F, the heater runs
automatically until the water is heated up to 3°C/37.4°F. This will help prevent water from freezing. If you are not going to use the spa in near future,
please disassemble the spa and store it following the storage procedure.
In Rainy days
For the spa that is placed outdoors, do not use it when it rains.
If the spa is placed under rain shelter, do not turn on the bubble function. This is because the rain in the nearby air will also be sucked into the pump,
causing the bubble generator to get damp and rusty which could result in malfunction and void your warranty.
It is recommended to put the plug and socket somewhere not exposed to rain to prevent damage caused by water accumulation due to excessive rain.
DISPOSAL AND ENVIRONMENTAL PROTECTION
This marking indicates that the product should not be disposed of with other household waste. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, recycle the product responsibly to promote the sustainable reuse of
material resources. Information on disposal can be obtained from your local authorities.
To return your used device, please use the return and collection systems or contact the retailer where the product was purchased for
environmentally safe recycling.
TROUBLESHOOTING
ERROR CODE CHART
LED READING
Signal wire is loose
- - - / 888 / EEP
Communication failed
Water temperature is below 0°C (32°F) or exceeds 50°C (122°F)
F0
Temperature sensor failure
F1 immediately shows after pressing FILTER , HEATING or UVC
F1
F1 shows 15s after pressing FILTER, HEATING or UVC
CAUSE
16
SOLUTION
Contact local MSpa Service Center
Contact local MSpa Service Center
Change the water
Contact local MSpa Service Center
Clean the parts and tubes that the water goes through
1. Add more water to the minimum line
2. Clean the parts and tubes that water goes through
3. Contact local MSpa Service Center