b.3 electrIcal connectIon
Familiarize yourself with the safety instructions as mentioned in chapter A.
The electrical connection must be carried out by qualified electrical engineers,
using the supplied cable and plug. Make sure to use a socket which can take the
load factor and voltage as indicated on the technical data table (see chapter H).
Make sure there is an efficient grounding which is in compliance with the standards
in force.
For safety during maintenance it is advised to install a single pole isolating
switch to enable the assurance of a complete disconnection of electricity.
b.3.1 Wiring diagram
Environment feeler
External thermostat
Blue
Red
Fumes Thermocouple
ALP = General safety pressure switch
ALT = General safety thermostat (manual reset)
Diagram 1
b.4 thermostat
The stove can work semi-automatically due to a thermostat. The thermostat is
placed at the back of the stove (see T in picture 4).
Make sure the temperature measurement of the stove is not influenced by any
other heat source than the stove itself.
It is possible to connect the stove to any kind of external thermostat. Use a cable
of 2x0.5 mm², protrude the cable through the pre-set hole. Connect the cables to
the relevant points at the electronic circuit board, see electrical diagram 1. These
operations must be carried out by a specialised technician.