Warning
Danger of explosion due to explosive gases
Injuries ranging from severe to fatal
In the event that the cells or batteries suffer a thermal runaway, avoid ignition sources.
If possible, provide sufficient ventilation.
3.7.2 Workflow for Basic and Premium
1. Open the transport container (see section 3.3.1).
2. Remove the battery.
3.7.3 Premium workflow
1. Open the transport container (see section 3.3.1).
2. Remove the cushions PP until the battery is visible.
3. Remove the battery.
4 Maintenance and repair
4.1 Maintenance
4.1.1 Safety instructions
Warning
Danger of poisoning due to toxic substances that have leaked from the cells or batteries
Injuries ranging from severe to fatal
Use protective equipment suitable for the dangerous goods involved.
4.1.2 Maintenance and cleaning instructions
Contamination by substances leaking from the cells or batteries on to the transport containers must be
removed. For this purpose, use only cleaning materials that do not attack the material of the transport
container (PP).
PyroBubbles® can generally be reused, provided that they show no visual changes and the granules are
odour-neutral. Damaged PE packing cushions must be replaced.
4.2 Repairs
Do not use damaged transport containers; they no longer meet the requirements of the approved type.
Repairs shall be made exclusively by the manufacturer or by a specialist authorized by the manufacturer.
Bedienungsanleitung FLEX-Box
GENIUS Technologie GmbH Willy-Brandt-Straße 9 • 72555 Metzingen / Germany
Telefon: + 49 (0) 3375 - 24 609 80 • Telefax: + 49 (0) 3375 - 24 609 88 • info@genius-group.de • www.genius-group.de
Copyrighted No duplication without prior approval PyroBubbles
Version: 1.0
All rights reserved © GENIUS Technologie GmbH
Seite / page: 39/40
®
is a registered trademark
Datum / date: 09.12.2024