6. Technical data
Model
Protection class
Rated power
Max. power
Electrical power supply
Rated current
Temperature range
Humidity of air range
Dehumidification performance at
(30°C/80%)
Refrigerant
Refrigerant quantity
Tank volume
Self purging
Air flow rate (m3/h)
Room area
Display
Weight
Subject to technical modifications!
7. Unpacking
• Open the packaging and carefully remove the de-
vice.
• Remove the packaging material, as well as the
packaging and transport safety devices (if present).
• Check whether the scope of delivery is complete.
• Check the device and accessory parts for transport
damage. In the event of complaints the carrier must
be informed immediately. Later claims will not be
recognised.
• If possible, keep the packaging until the expiry of
the warranty period.
• Familiarise yourself with the product by means of
the operating instructions before using for the first
time.
• With accessories as well as wearing parts and re-
placement parts use only original parts. Replace-
ment parts can be obtained from your dealer.
• When ordering please provide our article number
as well as type and year of manufacture for your
equipment.
m WARNING!
The device and the packaging material are not
children's toys! Do not let children play with
plastic bags, films or small parts! There is a dan-
ger of choking or suffocating!
24 | GB
DH6000x
IP20
850 W
1050 W
230 V~ / 50 Hz
3,9 A
5° - 35°C
30% - 80%
60 L/d
R290
210 g
6 L
Yes
350 m
/h
3
60 - 80 m
2
LCD
32 kg
www.scheppach.com
8. Montage
Attaching wheels and handle Fig. 2 + 3
1. Attach the wheels, support feet and handle.
2. Secure both sides of the support feet in the holes
provided on the casing using 3 screws each.
3. Insert the handle between the support feet and
screw both sides down.
4. To attach the wheels, first tighten the wheel axle
on the underneath of the dehumidifier..
5. Push the wheels on both sides of the axle and fix
them with a cotter pin.
9. Operation
1. Plug in the device. The device confirms this by a
signal tone. Now the display shows the environ-
mental moisture level.
2. The level of humidification can be set from 30%
(min.) up to 80% (max.). During this process
dehumidification mode-key flashes.
3. When you have reached the desired level wait for
5 seconds for the dehumidifier to save the value.
The dehumidification mode-key stops flashing and
the dehumidifier starts working. The display for en-
vironmental moisture level shows the difference.
4. Before operating, place machine on a horizontal,
stable surface.
5. The appliance shall be installed in accordance
with national wiring regulations.
6. The appliance is connected by the cord of
H05VV-F 3G 1.5mm
with plug.
2
Functions of Keys:
1.
On-/Off-Key (ON/OFF): Turn the device on and
off.
2. "Plus/Minus"-Keys: Set the desired Moisture
Level. Keep pressing the plus- or minus- key
(the value will run fluently towards the chosen
direction) and let go when the desired value is
reached.
3. "WIND"-Key: Set the speed for the dehumidifier.
Automatic defrosting function
At low temperatures the device will start defrost-
ing automatically. During this phase the cooling fan
works properly but the inserted compressor switches
itself off. The "Automatic Defrosting"-symbol and the
"WIND"-key flash.
Collection container for water
If the collection container is completely filled, the
symbol "Filling Level Indicator" will show this. In ad-
dition, there will be an acoustic signal (for 5 seconds)
and the device will stop dehumidifying.