1.Time Table
2.Temperature Table
3.Prepare to Place
4. Control Time
1. Adjust present time:
Press "H" to adjust the hour until the figure comes stable, then press "M" to
adjust minutes
2. Set temperature:
Press"P" to set temperature, then press"▲" or"▼"to control the
temperature until the figure comes stable after about 3 seconds(setting
range35-110℃/95-230℉, default temp is 60℃/140℉)
3. Work mode:
3.1 Normal working mode
Press "P" to start the sauna heater directly, its operation time can last
4hours.
3.2 Preset working mode
A. Auto-start setting (Max 24hours):
Press "Prepare to place" to fix the time, then press "H" and "M" to set time
before "P" to finish.
B. Auto-Stop setting (Min 10mins, Max 4hours):
Press "Control time" to adjust the time, then press "H" and "M" to set time,
before time table finishing blink.
Remark: Step 1, 3.1 and 3.2.A must be operated during unworking of
sauna heater; Step 2 and 3.2.B must be operated during working of
sauna heater)
4. TEMPERATURE SENSOR
For the recommendation of the minimum installation distances, please
check installation diagram of sauna heater for details (See fig1).
A heat resistant cable of 3 meters is provided with the control panel, which
can be extended to the outside of sauna room by normal weak current
cables.
5.Ozone Output (Optional)
6. Power of Room Light
7. Power of Heater