④ Minus key: temperature setting
Automatic lock function
When all the key no operation for 20 seconds, the key will be locked
automatically. After locking, the Increase key and Decrease key cannot be
operated. The unlock key and light / CF key operate normally
Automatic light off function
When all the key no operation for 10 minutes, the lamp will turn off
automatically
Adjustable range
Upper room:
lowest value: 5°C / 41°F
Maximum value: 18°C / 64°F
Lower chamber:
lowest value: 5°C / 41°F
Maximum value: 18°C / 64°F
Display range
Temperature display range of control board: 0 ~ 37 ° C / 32 ~ 99 ° F
Forced defrosting function
When the compressor works for 12 hours, the compressor will stop
working for 30 minutes
Memory function
The control board is re-energized after each power-off, the temperature
setting value,
Fahrenheit/Celsius state will be the same as before the power-off, and the
length of power-off time is not limited.
Display stability
In the Celsius state: When the temperature measured by the temperature
probe is within ± 1 ° C of the set temperature, the temperature display will
display the set temperature value
In the Fahrenheit state: When the temperature measured by the
temperature probe is within ± 2 ° F of the set temperature, the temperature
display will display the set temperature value
- 7 -