6.4 On/Off switch (8)
Press the "I" position on the switch (8) to switch
on the compressor. To switch off the compressor,
press the "0" position on the switch (8) (Fig. 1).
6.5 Adjusting the pressure: (Fig. 1,2)
•
You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7).
•
The set pressure can be taken from the quick-
lock coupling (5).
6.6 Setting the pressure switch
The pressure switch is set at the factory.
Switch-on pressure 6 bar
Switch-off pressure 8 bar
7. Replacing the power cable
Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
Danger!
Pull the power plug before doing any
cleaning and maintenance work on the ap-
pliance.
Warning!
Wait until the compressor has completely
cooled down. Risk of burns!
Warning!
Always depressurize the tank before carrying
out any cleaning and maintenance work.
Danger!
After use, always switch off the equipment
immediately and pull out the power plug.
8.1 Cleaning
•
Keep the safety devices free of dirt and dust
as far as possible. Wipe the equipment with a
clean cloth or blow it with compressed air at
low pressure.
•
We recommend that you clean the appliance
immediately after you use it.
•
Clean the appliance regularly with a damp
Anl_TC_AC_190_24_8_I_OF_SPK13.indb 14
Anl_TC_AC_190_24_8_I_OF_SPK13.indb 14
GB
cloth and some soft soap. Do not use
cleaning agents or solvents; these may be
aggressive to the plastic parts in the appli-
ance. Ensure that no water can get into the
interior of the appliance.
•
You must disconnect the hose and any
spraying tools from the compressor before
cleaning. Do not clean the compressor with
water, solvents or the like.
8.2 Condensation water (Fig. 1)
Notice! To ensure a long service life of the pres-
sure vessel (2), drain off the condensed water by
opening the drain valve (11) each time after using.
Check the pressure vessel for signs of rust and
damage each time before using. Do not use the
compressor with a damaged or rusty pressure
vessel. If you discover any damage, please con-
tact the customer service workshop.
8.3 Safety valve (10)
The safety valve has been set for the highest
permitted pressure of the pressure tank. It is
prohibited to adjust the safety valve or remove its
seal. Actuate the safety valve from time to time
to ensure that it works properly when required.
To inspect the safety valve, loosen the screw cap
carefully while the tank is pressurized. When you
open the cap, air will be released from the valve.
After you have opened the screw cap, tighten it
again completely.
8.4 Storage
Warning!
Pull the mains plug out of the socket and ventilate
the appliance and all connected pneumatic tools.
Switch off the compressor and make sure that it is
secured in such a way that it cannot be started up
again by any unauthorized person.
Important!
Store the compressor only in a dry location.
Always store upright, never tilted!
8.5 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
•
Type of machine
•
Article number of the machine
•
Identification number of the machine
•
Replacement part number of the part required
For our latest prices and information please go to
www.Einhell-Service.com
- 14 -
06.03.2025 13:14:47
06.03.2025 13:14:47