Herunterladen Inhalt Inhalt Diese Seite drucken

Exodraft RSV009-4-1 Bedienungsanleitung Seite 7

Vorschau ausblenden Andere Handbücher für RSV009-4-1:
Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 10
3000113-2011-06-22
Fitting the chimney fan onto the chimney
Step
Action
1
Attach the safety wire to the chimney (1). Use the screw and
rawl plug provided in the brickwork of the chimney or the
self-cutting screw if working on a steel chimney. Then fit the
wire through the hole in the bottom section and into the
wire clamp.
Gently tighten the safety wire, and crimp (2) the wire clamp
so that the fan is held safely in place when opened for servi-
cing or cleaning purposes.
The isolation switch (supplied as extra) should be fitted onto
the side of the chimney (3), so it is easily accessible when
servicing the fan. The armoured cable with connecting cable
should be mounted into the underside of the isolator and up
into the switch through the coupling.
2
Prior to use check that:
• The fan is closed and the fastening screws/wing screws
tightened (4)
• The safety wire is taut and the wire clamp crimped (5)
• The coupling nut on the armoured cable is tightened (6)
• The safety wire is securely attached to the chimney (7)
• That the user is aware that the fan must always be switc-
hed on whenever the fireplace or boiler is in use
• The transportation safety bracket has been removed
(RSV315, -400 and -450).
GB
7
Inhaltsverzeichnis
loading

Inhaltsverzeichnis