The operating instructions
1.Weight shortcut keys:M1 (500g)M2(1000g)M3(2500g)M4(5000g)。
2.Tare: Press "Tare" and the "real-time" weight reading of the filling
machine will be zero.
3.Setting: After pressing the "setting" key, the number in the "filling" column
of the display screen flashes.After inputting the number to be set, the
cursor stops flashing, after pressing the "setting key" , then the filling
weight is set . The number on the filling bar is displayed as the set weight.
★Note: Due to the different viscosity of honey, the system will not be able
to accurately fill the set weight . It is recommended to do the "calibration"
after filling several bottles. Firstly setting the weight to less than the filling
weight you require. For example:if you require to fill1000 grams,you can
set 950 grams first start filling.After the filling is completed, get another
electronic scale to weigh the error, and then press the "set" "Button to
compensate for error value,which will make the weight of each next bottle
more accurate."Manual mode" and "Automatic mode" are the same as
above! (See the video tutorial on page 7 for details)
4.Trigger: After pressing the "trigger" key, the number in the "trigger"
column of the display screen will flash, enter the number 5~15 grams less
than the empty bottle weight into the flashing cursor column, and the cursor
- 8 -