Error messages

Error message on
Possible cause
the display
The valve is sluggish or the
F1
valve drive is blocked.
The valve drive is not
F2
installed or the adjustment
range is too great
F3
Adjustment range too small
Batteries are almost com-
F4 + Battery
pletely empty, valve control
symbol
no longer possible
Direct teaching blocked by
F5
the HomeMatic Center
Antenna symbol
Radio reception fails
flashes
The batteries of the valve
Battery symbol
drive are very low
40
9

Emergency operation

If the valve must be adjusted by hand because of an
error that cannot be corrected (e.g. the batteries are
low and no replacements can be found at the time),
it is done as follows:
• Remove both batteries.
• Remove the adjustment knob by pressing on
the position indicated with (B).
• Set the adjustment knob on the pin indicated
with (A).
• Turn the adjustment knob: clockwise = warmer,
counterclockwise = colder.

10 Maintenance and cleaning

The product is maintenance-free besides possibly
requiring a battery change. Maintenance or repairs
are only to be done by trained professionals. Clean
the product using a soft, clean, dry and lint-free
cloth.
To remote heavier contamination, make the cloth
damp with lukewarm water. Cleaning agents that
contain solvents are not to be used because it can
harm the plastic housing and the labels.