MAINTENANCE
CAUTION:
Before working on the washer, disconnect the lug from the power supply
socket.
- to ensure good performance. check and clean the suction and detergent
filters after every 50 hours of operation.
- clean the nozzle with tool provided. remove the lance from the gun,
remove any dirt from the nozzle hole and rinse.
TROUBLESHOOTING
Disconnect from the electrical power supply before carrying out user
maintenance or checking is correct functioning. To avoid unnecessary
disappointments, you should check the following before contacting the
service organization.
In case problems other than the above occur, please contact your local
distributor.
Symptom
- Machine not plugged in
Machine
- Defective socket
- Fuse has blown
- Defective extension cord
- Pump sucking air
Fluctuating pres-
- Valve is dirty, worn out or
sure
- Pump seals worn out
Cause
- Plug in machine
- Try another socket
- Replace fuse
- Try without the extension cord
- Check that hoses and connections are
airtight
- Clean and replace or refer to local
- Clean and replace or refer to local