Safety device (DC) to "OFF"
Press to reset the DC protector
STORAGE
Long term storage of your machine will require some preventive
procedures to guard against deterioration.

DRAIN THE FUEL

- Remove the fuel tank cap, drain the fuel from the fuel tank
- Remove the cover, drain fuel from the carburetor by loosening the
drain screw.
ENGINE
- Remove the spark plug, pour in about one tablespoon of SAE 10W30
or 15W40 motor oil into the spark plug hole and reinstall the spark plug.
- Use the recoil starter to turn the engine over several times (with
ignition off).
- pull the recoil starter until you feel compression.
- Stop pulling.
- Clean exterior of the generator and apply a rust inhibitor.
- Store the generator in a dry, well ventilated place, with the cover place
over it.
- The generator must remain in a vertical position.