9 Using fall protection
► Connect the electric power tool to the power
outlet (3) or the socket (4).
8.2
Disconnecting the power sta‐
tion
► Turn the rotary switch to the
► Remove connected electric power tools.
► Remove the charging cable.
► Close the cover on the power outlet or socket.
9
Using fall protection
9.1
Using fall protection
► If work needs to be performed on a working
platform or safe scaffold, secure the power
station with the strap sling (1) and carabi‐
ner (2).
10 Transporting
10.1
Transporting the power station
► Turn the rotary switch to the
The battery modules are electrically separa‐
ted.
► Disconnect the power station.
► Ensure that the power station is in a safety-
compliant condition.
Carrying the power station
► Carry the power station by the carrying han‐
dle.
Transporting the power station in a vehicle
► Secure the power station so that it cannot tip
over or move.
► When packaging the power station, make sure
to pack the power station in such a way that
the following conditions are met:
– The power station cannot move in the pack‐
aging.
► Secure the packaging so that it cannot
move.
The power station is subject to the requirements
for transporting dangerous goods. The power
0458-014-9901-A
position.
1
2
position.
station is classified as UN 3480 (lithium-ion bat‐
teries) and has been tested in accordance with
the UN Manual of Tests and Criteria Part III,
Subsection 38.3.
The transport regulations can be found at
www.stihl.com/safety-data-sheets.
11 Storing
11.1
Storing the power station
STIHL recommends storing the power station in
a charged state between 40% and 60% (4 LEDs
light up in green).
► Turn the rotary switch to the
► Disconnect the power station.
► Store the power station in such a way that the
following conditions are met:
– The power station is out of the reach of chil‐
dren.
– The power station is clean and dry.
– The power station is in a closed room.
– The power station is not suspended from
the charging cable, the fall protection, the
frame or the carrying handle.
– The power station is not stored outside the
specified temperature limits,
NOTICE
■ If the power station is not stored as described
in this User Manual, the power station may
become deeply discharged and irreparably
damaged.
► Charge a discharged power station before
storing it. STIHL recommends storing the
power station in a charged state between
40% and 60% (4 LEDs light up in green).
► Do not store the power station outside the
specified temperature limits,
12 Cleaning
12.1
Cleaning the power station
► Turn the rotary switch to the
► Disconnect the power station.
► Clean the power station with a damp cloth.
13 Maintenance and Repairs
13.1
Maintaining or repairing the
power station
Users cannot maintain or repair the power sta‐
tion themselves.