INSTALLATION TOOLS

Power switch facility: install circuit-breaker, 32A water proof,
in the easy-operating place. Turn off the power switch after use to
protect the safety of computer system (that is :the position of "A"
in the following picture)
The power socket outlet: AC220V,BV=3*4MM2 ,16A waterproof
(that is :the position of "B" in the following picture)
Water supply: connect hoses(G1/2 male connector) marked with
cold or hot water supply respectively. Shut-off Valve should be
installed at the end of water supply pipe on the wall. (that is :the
position of "C" in the following picture)
Drain: The drain point should be just right above the end of
sewage pipe on the ground. IIf not, the distance between the drain
point and the end of sewage pipe should be less than 200mm. The
diameter of sewage pipe under floor shoule be 50mm ormore.(that
is :the position of "D" in the following picture)
Maintain area:Pls leave space 500mm or more round the cabin,so
as to maintain conveniently in future. (that is :the shadow in the
following picture)
Ground Wire: Its resistance is 4 0hm or less
The installation height of cabin is 2400mm or more.
9