offgnd
4.Protections,
Troubleshooting
4.1 Protections
PV Over
Current/Power
PV Short
Circuit
pv Reverse polarity
Ni
ht Reverse
Char
Reverse
Polarity
BATTI Over Voltage
BATTI Over Discharge
BATTI Overheating
BATTI
Low
Temperature(Lithium
Battery')
Controller Overheating
TVSHigh Voltage
Transients
4.2 Troubleshooting
Faults
henomenon
Charging LED indicator off during
daytime when sunshine falls on
PV modules
ro
erl
Wire connection
is correctthe
controller
is not workin
red on solid
Red fast flashing
1 System alarm a voltage fault
when using Lead-acid batten/
@Systemalarm an over
discharge fault when the BATTI
is 1 2V but set as 24V
@Systemalarm an over-voltage
fault
when
BATTI
set as
BATT2
set as
24V
General
information
Offgridtec GmbH
1m Gewerbepark
1 1
84307 Eggenfelden
WEEE-Reg.-Nr. DE37551136
Offgridtec
tec
& Maintenance
When the charging current or power of the PV array exceeds the controllers rated current
or
ower, it will be chan
When not in the PV charging state, the controller will not be damaged in case of a short-
circuitin
in PV arra
When the polarity of the PV array is reversed, the controller may not be damaged and
can continue to operate normally after the polarity is corrected.
NOTE: If the PV array is reversely connected to the controller,l
controller power(watts)from the PV array, will damage the controller.
in
Prevents
the
batte
Fully protected against battery' reverse polarity", no damage will occur to the battery.
Correct the miswire to resume normal operation.
NOTE: Limited to the characteristic
correct,
and batte
When the battery voltage reaches the overvoltage disconnect voltage, it will automatically
sto
batte
cha
When the batten,' voltage reaches the low voltage disconnect voltage, it will automatically
stop batten,' discharging to prevent battery damage caused by over-discharging. (Any
controller connected loads will be disconnected. Loads directly connected to the battery
will not be affected and ma continue to dischar
The controller
sensor.The controller stops working when its temperature exceeds 65 oc and restart to
work when its temperature is below 55 oc.
When the temperature detected by the optional temperature sensor is lower than the
Low-Temperature Protection Threshold(LTPT), t he controller will stop charging and
discharging automatically. When the detected temperature is higher than the LTPT,the
controller will be working automatically (The LTPTis O oc by default and can be set
within the ran e of 10 - -40 oc).
The controller is able to detect the temperature inside the battery. The controller stops
working when its temperature exceeds 85 oc and restart to work when its temperature
is below
75 oc.
The internal circuitry of the controller is designed with Transient Voltage Suppressors
(WS), which can only protect against high-voltage surge pulses with less energy. If the
controller is to be used in an area with frequent lightning strikes, it is recommended to
install
an external
Possible
PV array disconnection
Battery voltage is lower
than
8.5V
BATTI over discharged
BATTI Overheating
Incorrect wiring steps.
12V and
Contact
Tel: 08721
9199400
Email: info@offgridtec.com
Web: wvm_offgridtec.com
CEO:
Christian
& Martin
MPPT Pro Duo
ed at the rated current or
from
dischar
in
to the
of lithium battery, when the PV connection
connection
reversed,
in
to
revent
batte
dama
can detect the battery temperature
su
e arrester.
reasons
Confirm
tight
Please check the voltage of the battery. At least 8.5V
volta
When the battery' voltage is restored to or above
LVR(lowvoltage reconnect voltage), the load will
recover
The controller will automatically tum the system off.
When the temperature declines to be below 55 QC,
the
controller
@Disconnect t he system, a nd reconnect t he BATT2
first, then BATTI
@@Pleasesetthe systemvoltageon the controller
to match the BATTI voltage.
Account Sparkasse
Accoun
Nn: 10188985
BLZ
74351430
BAN:
DE69743514300010188985
BIC:BYLADEMI E GF(Eggenfelden)
Krannich
ower.
.5 times rated
PV module
at ni
ht
the controller
will be dama
e caused
b
over-char
e the batte
.)
through
an extemal temperature
Troubleshootin
that
PV wire
connections
e to activate
the controller.
will
resume.
Ronal-Inn
Seat
HRB: 9179 Registergericht
Tax
Ust-ldNr
Jurisdiction:
Seite
15 von 19
is
ed.
in
are
correct
and
and
district
court
Landshut
Number.
141/134/30045
DE2871
1 1500
Mühldoff
am
Inn

Werbung