5) ALARM (for temperature)
Press on "SET" until the "ALARM" symbol flashes and the display shows the current temperature. Then press
"UP" or "DOWN" to adjust the ideal temperature alarm difference.
6) Choice of mood : HUMI or DEHUMI
RH (real-time temperature)
Press on '"SET" until the "HUMI" symbol flashes. Then press "UP" or "DOWN" to choose between "HUMI" or
"DEHUMI".
7) DAY SET : day humidity setting
Press on "SET" until the "DAY SET" symbol flashes. Then press "UP" or "DOWN" to adjust the ideal humidity.
8) NIGHT SET : night humidity setting
Press on "SET" until the "NIGHT SET" symbol flashes. Then press "UP" or "DOWN" to adjust the ideal humidity.
9) DIFFERENCE (for humidity)
Press on "SET'" until the "DIFFERENCE" symbol flashes and the display shows the current value. Then press
"UP" or "DOWN" to adjust the ideal humidity difference.
10) ALARM (for humidity)
Press on "SET" until the "ALARM" symbol flashes and the display shows the current humidity level. Then press
"UP" or "DOWN" to adjust the ideal humidity alarm difference.
11) REAL TIME SELECTION
Press on "SET" to display the default time while the hour is flashing, then adjust the exact hour
using "UP" and "DOWN".
Then press "SET" to set the minutes in the same way.
12. Day start time
Press on "SET" to display the default hour value
to adjust the ideal Day start time hour.
13. Night start time
Press on "SET" to display the default hour value
"UP" or "DOWN" key to adjust the ideal Night start time hour.
Notes :
1- If the menu doesn't need to be adjusted, press "SET" directly for three seconds to save and exit the menu.
2- The thermostat will function normally after 15 seconds.
3- Adjusting parameters: press "UP" and "DOWN" for more than three seconds and the value will change more
rapidly.
Controlling function :
Cooling (COOL mode)
A.
A.Cooling systems work in below situation :
*The measuring temperature ≥ the set temperature + the temperature difference
**Cooling system works delay 1 minute : compressor delay.
B. Cooling systems stop working in the below situation : the measuring temperature ≤ the set temperature.
Heating (HEAT mode)
A.
.Heating systems works in below situation : the measuring temperature ≤ the set temperature - the
temperature difference.
B.
Heating systems stop working in below situation : the measuring temperature ≥ the set temperature
Dehumidification (DESHUMI mode)
A. Dehumidification systems work if the measuring humidity ≥ the set humidity + the humidity difference.
B. Dehumidification systems stop working if the measuring humidity ≤ the set humidity.
Humidification (HUMI mode)
A. Humidification systems work if the measuring humidity ≤ the set humidity - the humidity difference.
B. Humidification systems stop working if the measuring humidity ≥ the set humidity.