THERMOSTAT CONTROL HYGROMETER DTH Reptil'us
Thank you for buying one of our Reptil'us products. We hope it will give you full satisfaction.
Instructions :
The Reptil'us DTH Control hygrostat thermostat combines temperature and humidity control. It is widely used in
the reptile market, incubators and wherever temperature and humidity control is required.
One channel controls temperature, a second controls humidity.
Mains features :
1. Large LCD display, friendly interface, easy to read, operate and set the parameters.
2. Can set day/night temperature/humidity separately.
3. Background light automatically switches off after approx. 10 minutes without operation.
4. Small and elegant appearance, you can choose to mount it on the glass, place it on the table, or install it in the
aquarium and/or terrarium, depending on your needs
The following safety instructions must be respected to avoid any risk or electric shock.
-
Don't connect the wire terminals without electricity cut-off.
-
Don't put the product in contact with water or any other liquid.
-
Don't insert damp or defective batteries.
-
Don't handle the product with wet hands.
-
Don't disassemble the thermostat.
-
Don't install the thermo-hygrometer if it is wet/ damaged/ defective.
-
Don't use the appliance for any other purpose than that specified in the operating instructions.
-
This product should be kept out of the reach of children.
-
Please avoid overload, load short circuit, misuse, human damage etc., which is not covered by the
warranty.
WARNING : Don't use the machine under the environment of over damp, high temp, strong electromagnetic
interference or strong corrosion.
NOTES :
1.
The power supply should conform to the voltage value indicated in the instruction and keep stability
2.
To avoid interference, keep the probe away from the power cable.
MAIN FUNCTIONS AND PARAMETERS :
◆ Temperature control range : 16 ~ 42 ° C
◆ Temperature measure range : -40 ~ 100 ° C
◆ Humidity control range : 0 ~ 99%
◆ Humidity measure range : 0 ~ 99%
◆ Resolution : 0,1 ° C; 0,1%
◆ Accuracy : ± 1,0 ° C; ± 5%
◆ Time unit : hour (24:00 format)
◆ Relay capacity : 10A / 220V
◆ Input voltage : 220V ± 15% (standard), 50Hz ~ 60Hz
◆ Product consumption : ≤3W
◆ Outputs : resistive load ≤1100W / 220V, inductive load ≤275W / 220V, filament lamp ≤ 220 W/ 220V
Buttons :
A : Increase
V : Decrease
.
SET : Select