Reconnection Options

In the case of storage tanks with optional heating times, reconnection of the heating rods is to be carried out in
accordance with the circuit diagram pasted to the device. Switching installed at the factory is in line with the
6-hour heating time in ~ 230 V connection voltage. The polyphase circuits from 100 litres upwards, 3 ~
400 V and 3 N ~ 400 V, are also to be connected in accordance with the following table.
Reconnectable heating times and outputs at associated protection currents 16A.
Details in bold indicate switching undertaken at the factory (6 hours ~230 V)
Radiator connection*
Heating up time h
Tank capacity 50l
Tank capacity 80l
Tank capacity 100l
Tank capacity 120l
Tank capacity 150l
Tank capacity 200l
*S = side heating element in the flange
M = middle heating element in the flange

Connecting Diagram EKH-S, EKL, ES

L
1
~230V
1.1
TR
+°C
+°C
STB
1.2
B
D
A
R3
R1
Heating time Cable
3 1/3 h
A,B,C
4 h
A,C
8 h
B,C
16 h
A,C
30
Heating times with mains voltage
M
S
16
8
kW
0,30
0,65
kW
0,85
kW
1,10
kW
1,35
kW
1,65
kW
2,30
N
PE
L1
2
3
4
3~400V
2.1
3
1 .
1.1
TR
+°C
+°C
STB
2.2
3
2 .
1.2
M
A
C
R2
R3
Heating time Cable
at therm. terminal 1.2
3 1/3-4 h
D
at therm. terminal 2.2
at therm. terminal 1.2
B
remove
D
at therm. terminal 2.2
A
at therm. terminal 1.2
remove
D
at therm. terminal 2.2
remove
B
at therm. terminal 1.2
Tubular heating
element kW
Volume
r3
r1
r2
0,65
0,30
0,65
50 Liter
0,85
0,30
0,85
80 Liter
1,10
0,65
1,10
100 Liter
1,35
0,65
1,35
120 Liter
1.65
0,65
1,65
150 Liter
2,30
0,65
2,30
200 Liter
~230V
S+M
S+S
S+M+S
6
4
3 1/3
0,95
1,30
1,60
1,15
1,70
2,00
1,75
2,20
2,85
2,00
2,70
3,35
2,30
3,30
3,70
2,95
4,70
L2
L3
PE
1
2
3
4
3N~400V
2
1 .
3.1
TR
+°C
+°C
STB
2
2 .
3.2
B
C
R1
R2
Heating time Cable
A
at therm. terminal 1.2
3 1/3 h
B
at therm. terminal 2.2
C
at therm. terminal 3.2
D
remove
Reconnectable heating outputs in kW
(Switching installed at the factory 6 hours heating time)
~230V
16
8
6
4
3 1/3
h
h
h
h
h
0,30
0,65
0,95
1,30
1,60
0,85
1,15
1,70
2,00
1,10
1,75
2,20
2,85
1,35
2,00
2,70
3,35
1,65
2,30
3,30
3,70
2,30
2,95
4,70
Id. Nr.: 243701-5
3~400V
3N~400V
S+M+S in star
4
3 1/3
3 1/3
1,60
2,00
2,80
2,85
3,20
3,35
3,95
5,25
L1
L2
L3
N
PE
1
2
3
4
1.1
2.1
3.1
1.2
2.2
3.2
A
B
C
R3
R1
R2
A
at therm. terminal 1.2
B
at therm. terminal 2.2
C
at therm. terminal 3.2
D
remove
3~400V
3N~400V
4
3 1/3
3 1/3
h
h
h
1,60
2,00
2,80
2,85
3,20
3,35
3,95
5,25

Werbung

Kapitel

Inhaltsverzeichnis
loading

Verwandte Produkte für AE EKH-S

Diese Anleitung auch für:

EwhEklEs

Inhaltsverzeichnis