Verfügbare Sprachen

7.0
Press Menu for two seconds and then scroll the captions using +/ - until you reach "TEST I/0" on the screen.
This function can be accessed only when the stove is in stand-by mode and allows to check the
components. Only staff authorized by the Technical Assistance Service may access it and indeed it is
protected by a password.
CAPTIONS ON THE SCREEN
CO
C1 RESISTOR START
C2 RPM FAN SMOKE
C3 PELLET LOAD
C4 AIR FAN
C5 THERMOCOUPLE
C6 AIR FLOW
C7 °C TEMPERATURE SENSOR
C8 IR PROBE TESTING
C9 AUX OUTPUT
8.0
Press Menu for two seconds and then scroll the captions using +/ - until you reach "SETTINGS" (SETTAGGI)
on the screen. This Menu allows to regulate the main parameters used to adjust the functions of the stove.
Only staff authorized by the technical assistance service may access it and indeed it is protected by a
password.
END-OF-LINE COLD TESTING FUNCTION
READY FOR TESTING
TESTING THE IGNITION RESISTOR
TESTING THE SMOKE EXTRACTION
ENGINE
TESTING THE AUGER ENGINE
TESTING THE VENTILATION ENGINE
TESTING THE THERMOCOUPLE
TESTING THE FLOW SENSOR
TESTING THE ROOM AIR PROBE
TESTING THE REMOTE CONTROLLER
PROBE
TESTING THE SERIAL CABLE OF AUX
OUTPUT
TECHNICAL PARAMETERS
DESCRIPTION
Measurement Unit
//
//
RPS
A
V 100%
°C
Volt
°C
°C
ON-OFF
E N G