- when restarting the motor, always keep the trigger pressed.
NOTE:
THE MOTOR ONLY RUNS WHEN THE TRIGGER IS OPERATED.
CORRECT USE OF STANDARD ACCESSORIES
- The washer is equipped with adjustable nozzle.
- Jet adjustment from pencil to fan.
WARNING!
Do not adjust the nozzle while the triggter is squeezed.
RECOMMENDED CLEANING PROCDURE
- Dissolve dirt by applying detergent with the fan jet to the dry surface. On
vertical surfaces. Work from the bottom upwards. Leave the detergent
to act for 1 to 2 minutes, but do not allow to dry out. Apply the high from
the surface, working from the bottom upwards.
- Avoid allowing the rinsing water to run on the unwanted surfaces.
STORAGE
- Switch off the washer.
- Turn off the water supply tap.
- After use, the detergent residuals should be removed from the tank.
- Discharge residual pressure by pressing the trigger until no more water
comes out of the lance nozzle.
- Engage the gun safety lock.
- Remove the plug from the socket.
- Operate the washer with non-corrosive/non-toxic antifreeze before
storing for the winter.
18
Compact Induction High Pressure Washer 100bar