Herunterladen Diese Seite drucken

Ballu BCH/R-1500 Kurzanleitung Seite 4

Verfügbare Sprachen

Verfügbare Sprachen

4.1 Setting the program
To select a program to run:
1) Press the program select button, "mode" key, The current selected program will be displayed, factory default
program is"P4";
2) Continuous press "Mode", it will display P1-P2-P3-P4-P5-lJp-P1
3) 3 seconds later, LED window will return to display room temperature, The program select option will terminate and
the selected program will be saved and used to control the panel heater
4.2 Set the User Program "UP" mode
The "UP" program allows the heater to be set in comfort working mode at required times and each day of the week
can have different settings. Maximum three intervals in comfort working mode can be input. The rest of hours will
work underanti-frost mode with default temperature sett•ng 50C.
41.1 Press"Mode" to Choose "UP" mode;
4.1.2 Press"Prog", LED window will display "dl " and flash, it comes to program setting for Monday; Press "Time" could
choose dl ...„d7 to get the day want to make program setting;
4.1_3Press"Up" or "Down" key, it will display"1."and light will flash. It meanscould input the 1st time interval for
comfortable mode;
4.1.4 Press "Up" or "Down", it will display "O" for first time, continue press "Up" or "Down; it will display 1-2-3...22-23
until get the required starting hour, press "Time" to confirm the start hour.
4.1.5 press"Up" or "Down" until get the required finished hour, press "Time"to confirm the finished hour.
The userfinishesthe 1stinterval setting and switch to 2nd interval setting.
4.1.6 After confirm the 1st setting interval, it come to 2nd interval setting.
4.1.7 Repeat step 3 to 5 to set the 2nd and 3rd time interval for high heat output.
41.8 It could only be set in hour, not in minute.
4.1.9 Maximum 3 time intervals could be set in one day. If only need to set 1 or 2 intervals, just need to press"Time"
button to save the setting, it will come to next day.
4.1.10 Repeat above steps could set working program for one week.
4.1.11 During above setting, just press "Prog" or no any operation within 2 minutes, it will quit setting and save the
programs which had set.
Check the "UP" program setting
1) press"Prog"for 3 seconds,LEDwindow display "dl", it will show Monday program setting. press"Time" could
choose any day of a week to show the program setting;
2) press "Prog", it shows "1 press "Prog", it shows the 1st interval comfortable starting hour;
3) Press "Prog" again, it shows the 1st interval comfortable finish hour;
4) press "Prog", it shows
press "Prog", it shows the 2nd interval comfortable starting hour;
5)Press"Prog", i t showsthe 2nd interval comfortable finish hour;
6) Repeat the above steps to check dl -d7, if user wants to set one day, just press the Time key and select the date
which the user needs, then press "Prog"to check.
5. Children
lock
Press"Up" or "Down" at the same time for 3 seconds, all the buttons will be locked,
seonds. Press"Up" or "Down" at the same time for 3 seconds again, all buttons will be unlocked.
6. Open-window
function
1) When the heater is working, press window key for 3s,the open-window
2)When detect the room temperature is more than IOOClower than before in any half-hour,the heater will stop
working and the open-window
indicator light will be on.
3)When userspressthe open-window key for 35,the heater will recover the previous working mode. The open-
window indicator light will flash.
4) Press the open-window
key for 3s again and quit the window function, the open-window
Installation
the panel heater
This equipment was designed to be installed in a residence. Please ask your distributor before using it for any other
purpose. - The panel heater should be installed according to normal trade practice and in compliance with legislation
in the relevant country.
-The equipment
is class 1and is protected against splashed water IP 24. The device can be installed in a bathroom _
The device isto be installed so that switches and other controls cannot be touched by a person in the bath or shower.
- Comply with the minimum clearance distances for positioning of the panel (Figure 1).
-The wall bracket allows keeping a free space behind the device to not disturb its regulation. The distance between
the unit and the wall should
not be obstructed.
Do not install the panel heater In a draught that might affect adjustment (for example, under a central mechanical
ventilation
unit etc...)- - Under or in front of a fixed power socket or near curtains or other combustible materials.
• In a conform position, the air outlet grid and the control unit is visible in the upper part of the device. It isforbidden
to install a vertical unit horizontally and vice versa.
Wall Mounting:
Do not fit the castors to the base of the heater. Make sure the heater is unplugged from the mains power and the wall
is suitable for mounting the panel heater and there are the correct clearances. Make sure the panel heater iswithin 1
meter of a power socket. Detach the mounting bracket from the rear of the heater by compressing the 2 bracket clips,
pulling the clips out of the heater rear & removing the bracket hooks from the heater.
min
500
min
50
150
nmn
• Positon the bracket on the wall in the desired position & drill holes for two mounting screws.
- Once the holes are drilled, use two explosion screws (appropriate for the type of wall) to fix the bracket firmly in
place. Check for strength.
-put the bracket on the wall and tight it with two wall mounting screws.
-Carefully place the heater (slightly titled forward) onto the hooks at the bottom of the bracket (A).
-Then insert upper side of bracket in to the holes on the back cover of heater (B).
-Lock the wall mounting bracket by two lock screws (C).
Floor Mounting
The device can be mounted on special legs enabling to move it in the room.
Support foots are attached asfollows:
Turn the convector upside down;
Take one of support foots with rollers;
Placethe plate of the support foot to the attaching point on the convector sothat the dome-shaped part of the plate will be
tightly attached to the convector close to its rear panel the screw holes should match;
Tighten the support foots with the screws in parts kitting.
until it display the required program;
l" will light on LED window for 5
indicator light will on and flash.
indicator will off.
4
4,
4,
MAINTENANCE
The heater requires regular cleaning to ensure trouble free operation.
Unplug the heater from the mains supply before cleaning.
Ensure that the heater has been allowed to cool down completely before cleaning.
Periodically, clean the appliance with a dry cloth to remove the dust. Do not use detergents or abrasive products.
Using avacuum cleaner, clean the dust from the intake grill and the air output openings.
To clean behind the heater (when mounted on a wall), unfasten the two locking screws located on the top of the
mounting bracket, pressdown on the two release catches on the mounting bracket to tilt the heater forward.
Ensure the heater isdry before plugging back into the mains supply.
Ifthe applianceis not to be usedfor any lengthof time,'*verecommendreturning it to its original packageand storing
it in adry, dust-free place.
Trouble Shooting
-Thedevicedoesnot heat:Makesurethat the installationcircuitbreakersareswitchedon,or that the loadshedder(ifyou
have one) has not switched off the unit power supply. Check the air temperature in the room. For the device equipped,
check that the programmer is in Comfort mode.
- The unit is permanently heating: Make sure that it is not in a draft and that the temperature setting has not been
changed. - The unit does not carry out programming orders (Device equipped): Make sure that the programming unit is
being correctlyused(referto its user's manual).Thedevicewith electroniccontrolis equippedwith a microprocessor that
can be disturbed by some severe mains voltage disturbances (outside ECstandards defining the disturbance protection
level). If there are any problems (thermostat blocked, etc.) switch off the unit power supply (fuse, circuit breaker, etc.) for
about 5 minutes to allow the unit to start again. If this phenomenon occurs frequently, control the power supply by your
energy supplier.
-Thedevice isvery hot on the surface: I t is normal that the devicewhen working, the maximumsurfacetemperatureis
limited in accordance with standards. However, if you believe that your radiator is still too hot, make sure the power is
adapted to the surface of your room (we recommend 1OOW / m2) and the unit is not placed in a stream of air that would
disrupt its regulation.
Warranty conditions
KEEP THIS DOCUMENT IN A SAFEPLACE(This certificate should only be produced if you are making a complaint, attached
with the invoice of the purchase) The supplier provides a 24-month warranty from the date of sale. The warranty does
not cover faults caused by transportation, careless manipulation or unqualified installation. The warranty also does not
covereverydaywear andtear on the product.Anyalterationscarriedout on the product areconsidereda breachof the
warranty conditions. Present this certificate only in case of claim with your distributor or installer attaching your invoice.
The provisions of these warranty conditions are not exclusives of benefits for the purchaser of the legal guarantee for
defects and hidden defects that apply in any case in terms of articles 1641 and following of the Civil Code.
This information is shown onthe plate which can be seen on the left-side or behind the front grille of the unit
Bollö
c
D
A) Standards, quality labels
B) Commercia
name
C) Serial number
D) Manufacturer number
Voltage
Wattage
Type
BCH/R-ISOO
EL
1000
220
BCH/R-1800
EL
1 soo
240-50
BCH/R-2200
EL
2200
Type of Device
Serial number
Name
and address
Of the customer
Dealer stamp
Dimensions
(mm)
Rating
Length
Height
Depth
480
413
129
20
413
129
25
800
413
129
IP24
Weight
(kg)
3,93
5,33
loading

Diese Anleitung auch für:

Bch/r-1800Bch/r-2200Bch/r-1500 elBch/r-1800 elBch/r-2200 el